Improving the effectiveness of routine prenatal screening for major congenital heart defects

被引:230
作者
Carvalho, JS
Mavrides, E
Shinebourne, EA
Campbell, S
Thilaganathan, B
机构
[1] Royal Brompton Hosp, London SW3 6NP, England
[2] Gen Hosp St Georg, Sch Med, Fetal Med Unit, London, England
关键词
D O I
10.1136/heart.88.4.387
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the effectiveness of adding outlet views to the four chamber view in routine prenatal ultrasound screening for major congenital heart defects (CND) as performed by trained sonographers, and to compare the procedure with current practice. Design and setting: Prospective observational study at a London teaching hospital. Participants and methods: 9277 women booked at a single institution (80% had first trimester nuchal translucency measurement) due to have routine fetal cardiac screening using the four chamber and outflow tract views at > 18 weeks of gestation. Main outcome measure: Identification of major CHD in chromosomally normal and abnormal pregnancies antenatally or postnatally. Results: There were 40 abnormalities (4.3/1000), of which 30 were chromosomally normal (3.3/1000). The overall antenatal detection rate was 75% (95% confidence interval (CI) 59% to 87%) and 70% (95% CI 51% to 85%) for euploid pregnancies. Abnormal cardiac views accounted for 70% of all prenatal diagnoses, 30% of which were made at, 18 weeks. The sensitivity of cardiac views during the first scan at > 18 weeks was 52%. Of all patients undergoing nuchal translucency screening, 34 had major CHD, nine with increased nuchal translucency (26.5%). Factors influencing the results of this screening programme were training and audit of operators, adequate equipment for antenatal examination, ease of access, and low threshold for referral to specialised fetal echocardiography. Conclusion: Adding ventricular outlet views to the four chamber assessment of the heart at routine fetal anomaly scans at > 18 weeks is the most effective technique to detect CHD prenatally. The success of such a programme depends on an infrastructure committed to continuous in house training of obstetric ultrasonographers coupled with feedback from specialised fetal cardiologists, as well as adequate resource allocation to obstetric hospitals involved with antenatal screening.
引用
收藏
页码:387 / 391
页数:5
相关论文
共 27 条
[1]   EXTENDED FETAL ECHOCARDIOGRAPHIC EXAMINATION FOR DETECTING CARDIAC-MALFORMATIONS IN LOW-RISK PREGNANCIES [J].
ACHIRON, R ;
GLASER, J ;
GELERNTER, I ;
HEGESH, J ;
YAGEL, S .
BRITISH MEDICAL JOURNAL, 1992, 304 (6828) :671-674
[2]   Prevalence and clinical significance of cardiac murmurs in neonates [J].
Ainsworth, SB ;
Wyllie, JP ;
Wren, C .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1999, 80 (01) :F43-F45
[3]   FAMILIAL RECURRENCE OF CONGENITAL HEART-DISEASE IN A PROSPECTIVE SERIES OF MOTHERS REFERRED FOR FETAL ECHOCARDIOGRAPHY [J].
ALLAN, LD ;
CRAWFORD, DC ;
CHITA, SK ;
ANDERSON, RH ;
TYNAN, MJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (03) :334-337
[4]   Detection of transposition of the great arteries in fetuses reduces neonatal morbidity and mortality [J].
Bonnet, D ;
Coltri, A ;
Butera, G ;
Fermont, L ;
Le Bidois, J ;
Kachaner, J ;
Sidi, D .
CIRCULATION, 1999, 99 (07) :916-918
[5]   Current and potential impact of fetal diagnosis on prevalence and spectrum of serious congenital heart disease at term in the UK [J].
Bull, C .
LANCET, 1999, 354 (9186) :1242-1247
[6]   Recurrence risks in offspring of adults with major heart defects: results from first cohort of British collaborative study [J].
Burn, J ;
Brennan, P ;
Little, J ;
Holloway, S ;
Coffey, R ;
Somerville, J ;
Dennis, NR ;
Allan, L ;
Arnold, R ;
Deanfield, JE ;
Godman, M ;
Houston, A ;
Keeton, B ;
Oakley, C ;
Scott, O ;
Silove, E ;
Wilkinson, J ;
Pembrey, M ;
Hunter, AS .
LANCET, 1998, 351 (9099) :311-316
[7]   Efficacy of routine fetal ultrasound screening for congenital heart disease in normal pregnancy [J].
Buskens, E ;
Grobbee, DE ;
FrohnMulder, IME ;
Stewart, PA ;
Juttmann, RE ;
Wladimiroff, JW ;
Wess, J .
CIRCULATION, 1996, 94 (01) :67-72
[8]   First-trimester transabdominal fetal echocardiography [J].
Carvalho, JS ;
Moscoso, G ;
Ville, Y .
LANCET, 1998, 351 (9108) :1023-1027
[9]   EFFECTIVENESS OF ROUTINE ULTRASONOGRAPHY IN DETECTING FETAL STRUCTURAL ABNORMALITIES IN A LOW-RISK POPULATION [J].
CHITTY, LS ;
HUNT, GH ;
MOORE, J ;
LOBB, MO .
BRITISH MEDICAL JOURNAL, 1991, 303 (6811) :1165-1169
[10]   CONGENITAL HEART-DISEASE IN A COHORT OF 19,502 BIRTHS WITH LONG-TERM FOLLOW-UP [J].
HOFFMAN, JIE ;
CHRISTIANSON, R .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 42 (04) :641-647