RETRACTED: Coated graphite-epoxy ion-selective electrode for the determination of chromium(III) in oxalic medium (Retracted Article. See vol 75, pg 1150, 2008)

被引:19
作者
Khalil, S
Wassel, AA
Belal, FF
机构
[1] Cairo Univ, Fac Sci, Dept Chem, Fayoum Branch, Al Fayyum 63514, Egypt
[2] Natl Org Drug Control & Res, Cairo, Egypt
[3] King Saud Univ, Fac Pharm, Riyadh, Saudi Arabia
关键词
chromium(III) ion-selective electrode; coated raphite-epoxy conductor electrode potentiometry; PVC;
D O I
10.1016/j.talanta.2003.10.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A coated graphite-epoxy chromium(111) ion-selective electrode, based on the ion-pair between [Cr(oxalate)(3)](3-) anion and tricaprylmethylammonium cation (Aliquat 336) in a poly(vinylchloride) (PVC) matrix is constructed. A thin membrane film of this ion-pair, dibutylphthalate (DBP) in PVC was deposited directly onto a Perspex(R) tube containing a graphite-epoxy conductor substrate attached to the end of a glass tube. The effect of membrane composition (ion-pair, DBP and PVC), oxalate concentration, pH and some cations and anions upon the electrode response is investigated. The electrode shows a linear anionic response to E vs. log [Cr(3+)](i) in the chromium(III) concentration range from 2.9 x 10(-6) to 10(-2) mol l(-1), and a slope of -18.7 +/- 0.5 mV dec(-1), at pH working range of 2-8 and 0.3 mol l(-1) oxalate concentration. Variation in the potential of about 2 mV was observed during a working day of 7-8 h. The response time was less than 5 s and the life time of this electrode was superior to I year (over 1500 determinations by each polymeric membrane), with a practical detection limit of 2.1 x 10(-6) mol l(-1). Application of this electrode for chromium(III) determination in some food materials and various types of plants is described. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:303 / 307
页数:5
相关论文
共 37 条
[1]   Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene [J].
Abbaspour, A ;
Izadyar, A .
TALANTA, 2001, 53 (05) :1009-1013
[2]  
AGRAWAL C, 1989, INT J ENVIRON AN CH, V36, P95
[3]   Determination of chromium in urine samples by complexation-supercritical fluid extraction and liquid or gas chromatography [J].
Arancibia, V ;
Valderrama, M ;
Silva, K ;
Tapia, T .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (02) :303-309
[4]  
ARNOLD MA, 1986, ANAL CHEM, V58, pR84
[5]  
BARRAIS P, 1989, ANALUSIS, V17, P87
[6]   COATED WIRE ION SELECTIVE ELECTRODES [J].
CATTRALL, RW ;
FREISER, H .
ANALYTICAL CHEMISTRY, 1971, 43 (13) :1905-&
[7]   VOLTAMMETRIC ION-SELECTIVE ELECTRODE FOR CHROMIUM(VI) [J].
COX, JA ;
KULESZA, PJ ;
MBUGWA, MA .
ANALYTICAL CHEMISTRY, 1982, 54 (04) :787-789
[8]   Chromium determination in foods by quadrupole inductively coupled plasma-mass spectrometry with ultrasonic nebulization [J].
Cubadda, F ;
Giovannangeli, S ;
Iosi, F ;
Raggi, A ;
Stacchini, P .
FOOD CHEMISTRY, 2003, 81 (03) :463-468
[9]  
Davies R J, 1997, Sleep Med Rev, V1, P87, DOI 10.1016/S1087-0792(97)90011-3
[10]  
DONGHNI L, 1989, PHYS TEST CHEM ANAL, V25, P221