An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy

被引:108
作者
Ferreira, SLC
Lemos, VA
Moreira, BC
Costa, ACS
Santelli, RE
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Univ Fed Fluminense, Dept Geoquim, BR-24020007 Rio De Janeiro, Brazil
关键词
flame atomic absorption spectroscopy; copper; preconcentration;
D O I
10.1016/S0003-2670(99)00632-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line enrichment flow system has been developed in order to determine trace amounts of copper in seawater and biological samples. It is based on the chemical sorption of copper(II) ions onto a minicolumn packed with Amberlite XAD-2 resin loaded with calmagite reagent. After copper preconcentration, it was eluted by 1 mol l(-1) hydrochloric acid solution and determined directly by flame atomic absorption spectrometry (FAAS). A preconcentration factor of 32 in 13.5 ml of sample (3 min preconcentration time) was achieved by using the time-based technique. The detection limit (3 sigma) was 0.15 mu g l(-1) and the precision (assessed as the relative standard deviation) reached values within the range of 2.7-6.0% in copper solutions varying from 0.0 to 20 mu g l(-1) concentration, respectively. Chemical and flow variables as well as concomitant were studied in the developed procedure. The method was tolerant to other ions usually present in the analyzed samples. The proposed procedure was successfully applied to determine copper in biological certified reference material. Achieved recoveries of copper in samples of seawater and biological material, measured by standard addition technique proved also that the proposed procedure has a good accuracy. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:259 / 264
页数:6
相关论文
共 15 条
[1]  
CHENG KL, 1992, HDB ORGANIC REAGENT
[2]  
Christian Gary D, 1994, ANAL CHEM
[3]   Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system [J].
Enríquez-Domínguez, MF ;
Yebra-Biurrun, MC ;
Bermejo-Barrera, MP .
ANALYST, 1998, 123 (01) :105-108
[4]  
Fang Z., 1993, FLOW INJECTION SEPAR
[5]   Separation and preconcentration of cobalt after sorption onto amberlite XAD-2 loaded with 2-(2-thiazolylazo)-p-cresol [J].
Ferreira, SLC ;
de Brito, CF .
ANALYTICAL SCIENCES, 1999, 15 (02) :189-191
[6]   Preconcentration and determination of copper and zinc in natural water samples by ICP-AES after complexation and sorption on amberlite XAD-2 [J].
Ferreira, SLC ;
dos Santos, HC ;
Ferreira, JR ;
de Araújo, NML ;
Costa, ACS ;
de Jesus, DS .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 1998, 9 (06) :525-530
[7]   Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN [J].
Ferreira, SLC ;
de Brito, CF ;
Dantas, AF ;
de Araújo, NML ;
Costa, ACS .
TALANTA, 1999, 48 (05) :1173-1177
[8]  
FERREIRA SLC, IN PRESS TALAUTE
[9]   EXTRACTION OF METALS FROM AQUEOUS-SOLUTION WITH POLYURETHANE FOAM [J].
MALONEY, MP ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1980, 105 (1256) :1087-1097
[10]   Electrothermal atomic absorption spectrometric determination of copper(II) using a tungsten metal furnace after preconcentration onto chitosan [J].
Minamisawa, H ;
Arai, N ;
Okutani, T .
ANALYTICAL SCIENCES, 1999, 15 (03) :269-275