Experimental study on friction and wear properties of interpenetrating polymer network alginate-polyacrylamide hydrogels for use in minimally-invasive joint implants

被引:37
作者
Arjmandi, Mohammadreza [1 ]
Ramezani, Maziar [1 ]
Nand, Ashveen [2 ]
Neitzert, Thomas [1 ]
机构
[1] Auckland Univ Technol, Dept Mech Engn, Auckland 1010, New Zealand
[2] Unitec Inst Technol, Hlth & Commun & Environm & Anim Sci Network, Auckland 1025, New Zealand
关键词
Biomaterials; Tribology; Wear; Hydrogels; Cartilage replacement; ARTICULAR-CARTILAGE; LOAD-BEARING; LUBRICATION; POLYETHYLENE; INTERFACES;
D O I
10.1016/j.wear.2018.04.013
中图分类号
TH [机械、仪表工业];
学科分类号
120111 [工业工程];
摘要
Alginate/Polyacrylamide (ALG/PAAm) hybrid hydrogel was suggested as an orthopedic prosthesis due to its biocompatibility and promising properties. Their friction and wear performances, however, have remained under-explored. In this study, indentation tests were conducted to obtain the mechanical properties of ALG/PAAm interpenetrating polymer networks, while the tribological response was evaluated by reciprocating sliding motion against alumina ceramic ball. The hydrogel samples were synthesized using two different ratios of crosslinking agent (X.A%) to study the effect of crosslinking on wear resistance of the material. Various loads and sliding speeds were considered to simulate human gait/running cycle, with and without presence of bovine serum as lubricant. Mass loss was quantified by gravimetric measurement of dried samples before and after each test, while the wear volume was measured by profilometry. An increase in the crosslinker concentration resulted in improvements of up to 21% the elastic modulus and 32% the hardness. A trend was observed in mass loss increase with higher loading regardless of crosslinker concentration. However, under higher sliding speed less material was removed due to wear. With lubrication and under the highest load, the minimum mean friction coefficient was obtained for samples with 0.06 X.A% (0.010 +/- 2.6E-3) which is promising when compared to that of articular cartilage. Visual inspection of worn surfaces by electron microscopy revealed adhesion as the dominant wear mechanism. Overall, the hydrogels with higher crosslinking density were considered as a potential candidate, due to higher stiffness and better tribological performance under lubrication.
引用
收藏
页码:194 / 204
页数:11
相关论文
共 47 条
[1]
Hydrogels for Cartilage Regeneration, from Polysaccharides to Hybrids [J].
Anahi Sanchez-Tellez, Daniela ;
Tellez-Jurado, Lucia ;
Maria Rodriguez-Lorenzo, Luis .
POLYMERS, 2017, 9 (12)
[2]
[Anonymous], 2007, E254607 ASTM INT
[4]
Study on the tribological properties of pHEMA hydrogels for use in artificial articular cartilage [J].
Bavaresco, V. P. ;
Zavaglia, C. A. C. ;
Reis, M. C. ;
Gomes, J. R. .
WEAR, 2008, 265 (3-4) :269-277
[5]
Investigation of friction and surface degradation of innovative boundary lubricant functionalized hydrogel material for use as artificial articular cartilage [J].
Blum, Michelle M. ;
Ovaert, Timothy C. .
WEAR, 2013, 301 (1-2) :201-209
[6]
The effect of polyethylene glycol on the stability of pores in polyvinyl alcohol hydrogels during annealing [J].
Bodugoz-Senturk, Hatice ;
Choi, Jeeyoung ;
Oral, Ebru ;
Kung, Jean H. ;
Macias, Celia E. ;
Braithwaite, Gavin ;
Muratoglu, Orhun K. .
BIOMATERIALS, 2008, 29 (02) :141-149
[7]
Poly(vinyl alcohol)-acrylamide hydrogels as load-bearing cartilage substitute [J].
Bodugoz-Senturk, Hatice ;
Macias, Celia E. ;
Kung, Jean H. ;
Muratoglu, Orhun K. .
BIOMATERIALS, 2009, 30 (04) :589-596
[8]
Brand Richard A, 2005, Iowa Orthop J, V25, P82
[9]
CHA WI, 1993, MAKROMOL CHEM, V194, P2433
[10]
Friction characteristics of a potential articular cartilage biomaterial [J].
Covert, RJ ;
Ott, RD ;
Ku, DN .
WEAR, 2003, 255 :1064-1068