Digital tomosynthesis mammography using a parallel maximum likelihood reconstruction method

被引:34
作者
Wu, T [1 ]
Zhang, JM [1 ]
Moore, R [1 ]
Rafferty, E [1 ]
Kopans, D [1 ]
Meleis, W [1 ]
Kaeli, D [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
来源
MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2 | 2004年 / 5368卷
关键词
tomosynthesis; breast imaging; 3-D reconstruction; parallel computation; iterative reconstruction;
D O I
10.1117/12.534446
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A parallel reconstruction method, based on an iterative maximum likelihood (ML) algorithm, is developed to provide fast reconstruction for digital tomosynthesis mammography. Tomosynthesis mammography acquires 11 low-dose projections of a breast by moving an x-ray tube over a 50degrees angular range. In parallel reconstruction, each projection is divided into multiple segments along the chest-to-nipple direction. Using the 11 projections, segments located at the same distance from the chest wall are combined to compute a partial reconstruction of the total breast volume. The shape of the partial reconstruction forms a thin slab, angled toward the x-ray source at a projection angle 0degrees. The reconstruction of the total breast volume is obtained by merging the partial reconstructions. The overlap region between neighboring partial reconstructions and neighboring projection segments is utilized to compensate for the incomplete data at the boundary locations present in the partial reconstructions. A serial execution of the reconstruction is compared to a parallel implementation, using clinical data. The serial code was run on a PC with a single PentiumIV 2.2GHz CPU. The parallel implementation was developed using MPI and run on a 64-node Linux cluster using 800MHz Itanium CPUs. The serial reconstruction for a medium-sized breast (5cm thickness, 11 cm chest-to-nipple distance) takes 115 minutes, while a parallel implementation takes only 3.5 minutes. The reconstruction time for a larger breast using a serial implementation takes 187 minutes, while a parallel implementation takes 6.5 minutes. No significant differences were observed between the reconstructions produced by the serial and parallel implementations.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 15 条
[1]   An adapted fan volume sampling scheme for 3-D algebraic reconstruction in linear tomosynthesis [J].
Bleuet, P ;
Guillemaud, R ;
Desbat, L ;
Magnin, I .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2366-2372
[2]   Digital x-ray tomosynthesis: current state of the art and clinical potential [J].
Dobbins, JT ;
Godfrey, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :R65-R106
[3]   Optimization of matrix inverse tomosynthesis [J].
Godfrey, DJ ;
Warp, RJ ;
Dobbins, JT .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :696-704
[5]  
Kopans D. B., 1997, BREAST IMAGING
[6]   A theoretical framework for filtered backprojection in tomosynthesis [J].
Lauritsch, G ;
Harer, WH .
MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 :1127-1137
[7]   3-DIMENSIONAL IMAGE-RECONSTRUCTION BY DIGITAL TOMO-SYNTHESIS USING INVERSE FILTERING [J].
MATSUO, H ;
IWATA, A ;
HORIBA, I ;
SUZUMURA, N .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :307-313
[8]   Digital Tomosynthesis in breast imaging [J].
Niklason, LT ;
Christian, BT ;
Niklason, LE ;
Kopans, DB ;
Castleberry, DE ;
OpsahlOng, BH ;
Landberg, CE ;
Slanetz, PJ ;
Giardino, AA ;
Moore, R ;
Albagli, D ;
DeJule, MC ;
Fitzgerald, PF ;
Fobare, DF ;
Giambattista, BW ;
Kwasnick, RF ;
Liu, JQ ;
Lubowski, SJ ;
Possin, GE ;
Richotte, JF ;
Wei, CY ;
Wirth, RF .
RADIOLOGY, 1997, 205 (02) :399-406
[9]  
RAFFERTY EA, 2002, RSNA ANN M
[10]  
Rafferty EA, 2003, ARRS ANN M