Trends in basalt and sediment core contamination during IODP Expedition 301

被引:68
作者
Lever, Mark Alexander
Alperin, Marc
Engelen, Bert
Inagaki, Fumio
Nakagawa, Satoshi
Steinsbu, Bjorn Olav
Teske, Andreas
机构
[1] Univ N Carolina, Dept Marine Sci, Chapel Hill, NC 27599 USA
[2] Univ Oldenburg, Inst Chem & Biol Meeres, D-2900 Oldenburg, Germany
[3] Japan Agcy Marine Earth Sci & Technol, SUGAR Project, Extremobiosphere Res Ctr, Yokosuka, Kanagawa, Japan
[4] Univ Bergen, Dept Earth Sci, Bergen, Norway
[5] Univ N Carolina, Dept Marine Sci, Chapel Hill, NC USA
关键词
perfluorocarbon; tracer; chemical; basalt; sediment; subsurface; marine; ODP; IODP;
D O I
10.1080/01490450600897245
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Perfluorocarbon tracers (PFTs) are used during cruises of the Ocean Drilling Program (ODP) and Integrated Ocean Program (IODP) to measure sample contamination with drilling fluid. Drilling fluid is supplied with a constant PFT concentration that can then be detected and quantified in sediment and basalt core samples. During IODP Expedition 301, we used washing (2x) and flaming to effectively remove PFT from the exterior of basalt rocks. Near-complete removal from the exterior allowed us to demonstrate that the interior of basalts was only minutely, if at all, contaminated with drilling fluid. We examined horizontal and vertical trends in sediment core contamination. Contamination decreased greatly between the core exterior to halfway along the core radius, and slightly from halfway to the center of cores, and was generally very low in halfway and center portions. Clay cores were, on average, more contaminated than cores with fine sand. Contamination was typically highest in the two uppermost sections (sections 1 and 2) and lower below (sections 3-5). There was no relationship between depth of core origin and contamination. To determine mechanisms of contamination in halfway and interior parts of cores, we estimated the diffusive flux of PFT from the core liner towards the core center. Based on conservative estimates, we concluded that diffusion did not account for any of the PFT measured in halfway and interior parts of cores in this study. Any measurable PFT concentrations in halfway and center parts of cores were caused by advection.
引用
收藏
页码:517 / 530
页数:14
相关论文
共 28 条
[1]  
[Anonymous], PROBABILITY STAT
[2]   SURVIVAL OF MAMMALS BREATHING ORGANIC LIQUIDS EQUILIBRATED WITH OXYGEN AT ATMOSPHERIC PRESSURE [J].
CLARK, LC ;
GOLLAN, F .
SCIENCE, 1966, 152 (3730) :1755-&
[3]   INNOVATIVE TECHNIQUES FOR COLLECTION OF SATURATED AND UNSATURATED SUBSURFACE BASALTS AND SEDIMENTS FOR MICROBIOLOGICAL CHARACTERIZATION [J].
COLWELL, FS ;
STORMBERG, GJ ;
PHELPS, TJ ;
BIRNBAUM, SA ;
MCKINLEY, J ;
RAWSON, SA ;
VEVERKA, C ;
GOODWIN, S ;
LONG, PE ;
RUSSELL, BF ;
GARLAND, T ;
THOMPSON, D ;
SKINNER, P ;
GROVER, S .
JOURNAL OF MICROBIOLOGICAL METHODS, 1992, 15 (04) :279-292
[4]  
Crank J, 1975, MATH DIFFUSION, P71
[5]   Landfill methane emissions measured by enclosure and atmospheric tracer methods [J].
Czepiel, PM ;
Mosher, B ;
Harriss, RC ;
Shorter, JH ;
McManus, JB ;
Kolb, CE ;
Allwine, E ;
Lamb, BK .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1996, 101 (D11) :16711-16719
[6]  
D'Hondt SL, 2003, P OCEAN DRILLING PRO, V201, P1, DOI [DOI 10.2973/ODP.PROC.IR.201.102.2003, DOI 10.2973/0DP.PR0C.IR.201.102.2003]
[7]  
DRAXLER RR, 1991, ATMOS ENVIRON, V12, P285
[8]  
FISHER AT, 2005, P INT OC DRILL PROGR, V301, pCH6
[9]   EVALUATION OF PERFLUOROMETHYLDECALIN AS A DELIBERATE TRACER FOR THE STUDY OF WATER MIXING PROCESSES [J].
FOGELQVIST, E ;
KRYSELL, M ;
OHMAN, P .
MARINE CHEMISTRY, 1989, 26 (04) :339-349
[10]  
Graber KK, 2002, 31 ODP