Esophageal impedance monitoring: The ups and downs of a new test

被引:21
作者
Shay, S [1 ]
机构
[1] Cleveland Clin Fdn, Dept Gastroenterol, Cleveland, OH 44195 USA
关键词
D O I
10.1111/j.1572-0241.2004.40119.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Impedance monitoring was first proposed as a method for gastrointestinal motility 10 yr ago. It detects changes in resistance to current flow when a bolus traverses an electrode pair, and can distinguish liquid (low-impedance) from gas (high-impedance) boluses (1). Electrode pairs placed at multiple sites on a standard solid-state esophageal manometry catheter can track antegrade bolus transit through the esophagus to correlate with manometry findings. In contrast, the electrode pairs placed at multiple sites on a standard pH probe can track retrograde bolus transit from the stomach to the esophagus to correlate with pH. This issue of The American Journal of Gastroenterology contains reports that relate to each of these two distinct applications of impedance monitoring.
引用
收藏
页码:1020 / 1022
页数:3
相关论文
共 19 条
[1]  
Al-Zaben A, 2002, BIOMED SCI INSTRUM, V38, P263
[2]  
[Anonymous], 1991, J GASTROINTEST MOTIL, V3, P151, DOI DOI 10.1111/J.1365-2982.1991.TB00061.X
[3]  
BLOM D, 2001, GASTROENTEROLOGY, V120, pA103
[4]   Esophageal motility in reflux disease before and after fundoplication: A prospective, randomized, clinical, and manometric study [J].
Fibbe, C ;
Layer, P ;
Keller, J ;
Strate, U ;
Emmermann, A ;
Zornig, C .
GASTROENTEROLOGY, 2001, 121 (01) :5-14
[5]  
KAWAMURA O, 2004, AM J GASTROENTEROL, DOI DOI 10.1111/J.1572-0241.2004.30349.X.
[6]   Is ineffective peristalsis really ineffective? [J].
Nguyen, NQ ;
Rigda, R ;
Tippett, M ;
Smout, AJ ;
Holloway, RH .
GASTROENTEROLOGY, 2003, 124 (04) :A161-A161
[7]   Twenty-four hour ambulatory simultaneous impedance and pH monitoring: A multicenter report of normal values from 60 healthy volunteers [J].
Shay, S ;
Tutuian, R ;
Sifrim, D ;
Vela, M ;
Wise, J ;
Balaji, N ;
Zhang, X ;
Adhami, T ;
Murray, J ;
Peters, J ;
Castell, D .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2004, 99 (06) :1037-1043
[8]   Multichannel intraluminal impedance (MII) in the evaluation of patients with persistent GERD symptoms despite proton pump inhibitors (PPI): A multicenter study [J].
Shay, S ;
Sifrim, D ;
Tutuian, R ;
Zhang, X ;
Vela, M ;
Castell, DO .
GASTROENTEROLOGY, 2003, 124 (04) :A537-A537
[9]   Multichannel intraluminal impedance accurately detects fasting, recumbent reflux events and their clearing [J].
Shay, SS ;
Bomeli, S ;
Richter, J .
AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 2002, 283 (02) :G376-G383
[10]  
Sifrim D, 2000, GASTROENTEROLOGY, V118, pA488