Continuous non-invasive measurement of mean blood pressure in fingers by volume-clamp and differential oscillometric method

被引:26
作者
Jagomagi, K [1 ]
Talts, J [1 ]
Raamat, R [1 ]
Lansimies, E [1 ]
机构
[1] KUOPIO UNIV HOSP, DEPT CLIN PHYSIOL & NUCL MED, FIN-70211 KUOPIO, FINLAND
来源
CLINICAL PHYSIOLOGY | 1996年 / 16卷 / 05期
关键词
blood pressure; finger blood pressure; FINAPRES; monitoring; noninvasive blood pressure;
D O I
10.1111/j.1475-097X.1996.tb01020.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The present study compares two different methods for non-invasive beat-to-beat finger arterial blood pressure monitoring. The measurements using the volume clamp method (FINAPRES, Ohmeda, USA) were compared with measurements applying the differential oscillometric method (UT9201 device, University of Tartu). 13 healthy volunteers were studied at rest, during head-up tilt (HUT) and during deep breathing (DB) with a fixed rate of 6 breaths/min. Blood pressure was recorded from adjacent fingers of the right hand. 150 pairs of mean blood pressure values in each subject were included for statistical evaluation. No systematic differences between the two methods were found. The difference between values (FINAPRES - UT9201) at rest was -1.1 mmHg (SD 5.5), during HUT 0.5 mmHg (SD 6.9) and during DB -3.6 mmHg (SD 7.7). The insignificant differences between the results obtained by the two independent methods allow us to conclude that both methods give reliable data on finger mean arterial pressure.
引用
收藏
页码:551 / 560
页数:10
相关论文
共 17 条
[1]  
[Anonymous], NONINVASIVE CONTINUO
[2]  
BAUM K, 1991, NONINVASIVE CONTINUO, P85
[3]  
CURIO I, 1991, NONINVASIVE CONTINUO, P51
[4]   NONINVASIVE VS INVASIVE BEAT-TO-BEAT MONITORING OF BLOOD-PRESSURE [J].
GABRIEL, A ;
LINDBLAD, LE ;
ANGLERYD, C .
CLINICAL PHYSIOLOGY, 1992, 12 (02) :229-235
[5]  
Imholz B P, 1991, Clin Auton Res, V1, P43, DOI 10.1007/BF01826057
[6]  
IMHOLZ BPM, 1992, J HYPERTENS, V10, P979
[7]   CONTINUOUS NON-INVASIVE BLOOD-PRESSURE MONITORING - RELIABILITY OF FINAPRES DEVICE DURING THE VALSALVA MANEUVER [J].
IMHOLZ, BPM ;
VANMONTFRANS, GA ;
SETTELS, JJ ;
VANDERHOEVEN, GMA ;
KAREMAKER, JM ;
WIELING, W .
CARDIOVASCULAR RESEARCH, 1988, 22 (06) :390-397
[8]   NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT DURING ORTHOSTATIC STRESS COMPARED TO INTRAARTERIAL PRESSURE [J].
IMHOLZ, BPM ;
SETTELS, JJ ;
VANDERMEIRACKER, AH ;
WESSELING, KH ;
WIELING, W .
CARDIOVASCULAR RESEARCH, 1990, 24 (03) :214-221
[9]   THE FINAPRES 2300E FINGER CUFF - THE INFLUENCE OF CUFF APPLICATION ON THE ACCURACY OF BLOOD-PRESSURE MEASUREMENT [J].
JONES, RDM ;
KORNBERG, JP ;
ROULSON, CJ ;
VISRAM, AR ;
IRWIN, MG .
ANAESTHESIA, 1993, 48 (07) :611-615
[10]  
Kurki T, 1987, J Clin Monit, V3, P6, DOI 10.1007/BF00770876