The effect of total knee arthroplasty design on extensor mechanism function

被引:93
作者
Mahoney, OM [1 ]
McClung, CD [1 ]
dela Rosa, MA [1 ]
Schmalzried, TP [1 ]
机构
[1] Athens Orthoped Clin PA, Athens, GA USA
关键词
total knee; kinematics; extensor mechanism; function;
D O I
10.1054/arth.2002.32168
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The effect of total knee arthroplasty design on extensor mechanism function was evaluated prospectively in a consecutive, single-surgeon series. Group I knees (n = 83) were implanted with a prosthesis that has a multiradius femoral component, and group 2 knees (n = 101) were implanted with a femoral prosthesis that has a single flexion-extension axis. Group 2 knees gained flexion more rapidly: At 6 weeks, the average flexion for was 94.5degrees for group 1 and 107.1degrees for group 2 (P<.001). Significantly more patients with group 2 knees were able to arise front a 16-inch (low) chair without using their arms starting at 6 weeks, and a difference was maintained through 2 years (90% vs 73%; P=.003). Patients with group 2 knees had significantly less anterior knee pain when rising from a seated position starting at 6 weeks, and a difference was maintained through 2 years (1% vs 22%; P=.001).
引用
收藏
页码:416 / 421
页数:6
相关论文
共 19 条
[1]
Barrack R L, 2000, J Am Acad Orthop Surg, V8, P75
[2]
BRAUNE W, 1891, SACHSISCHEN GESELLSC, V17, P75
[3]
BUGNION E, 1892, MECH GENOU EXTRAIT R
[4]
Charnley J., 1979, LOW FRICTION ARTHROP
[5]
Churchill DL, 1998, CLIN ORTHOP RELAT R, P111
[6]
FICK R, 1911, HDB ANATOMIE MECH GE, V2, P109
[7]
FICK R, 1911, HDB ANATOMIE MECH GE, V3, P538
[8]
PATELLOFEMORAL COMPLICATIONS FOLLOWING TOTAL KNEE ARTHROPLASTY - CORRELATION WITH IMPLANT DESIGN AND PATIENT RISK-FACTORS [J].
HEALY, WL ;
WASILEWSKI, SA ;
TAKEI, R ;
OBERLANDER, M .
JOURNAL OF ARTHROPLASTY, 1995, 10 (02) :197-201
[9]
HOLLISTER AM, 1993, CLIN ORTHOP RELAT R, P259
[10]
Huang CH, 1996, CLIN ORTHOP RELAT R, P147