Conducting polymer sensors for monitoring aromatic hydrocarbons using an electronic nose

被引:58
作者
Barisci, JN
Wallace, GG
Andrews, MK
Partridge, AC
Harris, PD
机构
[1] Univ Wollongong, Dept Chem, Intelligent Polymer Res Inst, Wollongong, NSW 2522, Australia
[2] Ind Res Ltd, Lower Hutt, New Zealand
基金
澳大利亚研究理事会;
关键词
BTEX compounds; polymer sensors; electronic nose;
D O I
10.1016/S0925-4005(02)00033-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The possibility of detecting volatile aromatic hydrocarbons using the concept of an electronic nose is demonstrated. An array of sensors based on polypyrrole polymers has been used to identify and quantify the benzene, toluene, ethyl benzene, xylene (BTEX) compounds. A number of dopants have been investigated in terms of their ability to form suitable electrochemically deposited polymer films and to detect the analyte gases with sufficient sensitivity and reproducibility. A group of eight polymers has been found to meet most of the requirements for this application. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:252 / 257
页数:6
相关论文
共 17 条
[1]  
[Anonymous], 1996, HDB BIOSENSORS ELECT
[2]   Studies of the preparation and analytical application of polypyrrole-coated microelectrodes for determination of aluminum [J].
Barisci, JN ;
Murray, P ;
Small, CJ ;
Wallace, GG .
ELECTROANALYSIS, 1996, 8 (04) :330-335
[3]   Development of an electronic nose [J].
Barisci, JN ;
Andrews, MK ;
Harris, P ;
Partridge, AC ;
Wallace, GG .
SMART ELECTRONICS AND MEMS, 1997, 3242 :164-171
[4]   Polypyrrole based aroma sensor [J].
de Souza, JEG ;
Neto, BB ;
dos Santos, FL ;
de Melo, CP ;
Santos, MS ;
Ludermir, TB .
SYNTHETIC METALS, 1999, 102 (1-3) :1296-1299
[5]   A MULTISENSOR SYSTEM FOR BEER FLAVOR MONITORING USING AN ARRAY OF CONDUCTING POLYMERS AND PREDICTIVE CLASSIFIERS [J].
GARDNER, JW ;
PEARCE, TC ;
FRIEL, S ;
BARTLETT, PN ;
BLAIR, N .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 18 (1-3) :240-243
[6]   The prediction of bacteria type and culture growth phase by an electronic nose with a multi-layer perceptron network [J].
Gardner, JW ;
Craven, M ;
Dow, C ;
Hines, EL .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (01) :120-127
[7]  
GUISEPPIELIE A, 1998, HDB CONDUCTING POLYM
[8]   Resistance characteristics of conducting polymer films used in gas sensors [J].
Harris, PD ;
Arnold, WM ;
Andrews, MK ;
Partridge, AC .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 42 (03) :177-184
[9]  
IMISIDES MD, 1996, CHEM TECH, V5, P19
[10]   Chemical modulation of work function as a transduction mechanism for chemical sensors [J].
Janata, J ;
Josowicz, M .
ACCOUNTS OF CHEMICAL RESEARCH, 1998, 31 (05) :241-248