Evaluation of a new etest for detecting metallo-β-lactamases in routine clinical testing

被引:180
作者
Walsh, TR
Bolmström, A
Qwärnström, A
Gales, A
机构
[1] Univ Bristol, Dept Pathol & Microbiol, Bristol BS8 1TD, Avon, England
[2] AB BIODISK, Solna, Sweden
[3] Univ Iowa, Iowa City, IA 52242 USA
关键词
D O I
10.1128/JCM.40.8.2755-2759.2002
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Several Etest (AB BIODISK, Solna, Sweden) gradient formats were developed for detection of metallo-beta-lactamases based on the reduction of imipenem (IP) or ceftazidime (TZ) MICs in the presence of EDTA or 2-mercaptopropionic acid (MPA). The Etest metallo-beta-lactamase (Etest MBL) strips consisted of a double-sided seven-dilution range of IP or TZ (4 to 256 mug/ml) and IP or TZ (1 to 64 mug/ml) overlaid with a constant concentration of EDTA or MPA. The prototype strips were evaluated on several agar media (brain heart infusion agar, Isosensitest agar, nutrient agar, and Mueller-Hinton agar for aerobes and brucella blood agar for anaerobes) with 138 challenge strains: Acinetobacter spp. (n = 9), Aeromonas spp. (n = 8), Chryseobacterium spp. (n = 28), Escherichia coli (n 1), Klebsiella pneumoniae (n = 4), Pseudomonas aeruginosa (n = 14), Proteus mirabilis (n = 3), Serratia spp. (n 10), Stenotrophomonas maltophilia (n = 43), Sphingobacterium spp. (n = 3), and Bacteroides fragilis group (n = 15). PCR analysis using specific primers for IMP-1, L1, CcrA, and bla(B/C) confirmed the presence of the metallo-beta-lactamase genes. Enzyme assays were also performed with IP as an indicator substrate followed by EDTA inhibition profiles. EDTA was found to be a better inhibitor of metallo-beta-lactamases, especially for anaerobes. IP was a better than TZ. Mueller-Hinton agar was the preferred medium, particularly when compared to Isosensitest agar, which frequently produced falsely low MICs for IP. Etest IP plus IP-EDTA with Mueller-Hinton agar had a sensitivity of 94% (79 of 84) and specificity of 95% (124 of 130). The Etest MBL strip appears to be an acceptable diagnostic reagent to detect metallo-beta-lactamase phenotypes in the clinical microbiology laboratory.
引用
收藏
页码:2755 / 2759
页数:5
相关论文
共 36 条
  • [2] [Anonymous], 1981, STAT METHODS RATES P
  • [3] Arakawa Y, 2000, J CLIN MICROBIOL, V38, P40
  • [4] Plasmid location and molecular heterogeneity of the L1 and L2 β-lactamase genes of Stenotrophomonas maltophilia
    Avison, MB
    Higgins, CS
    von Heldreich, CJ
    Bennett, PM
    Walsh, TR
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2001, 45 (02) : 413 - 419
  • [5] Genetic diversity of carbapenem-hydrolyzing metallo-β-lactamases from Chryseobacterium (Flavobacterium) indologenes
    Bellais, S
    Poirel, L
    Leotard, S
    Naas, T
    Nordmann, P
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2000, 44 (11) : 3028 - 3034
  • [6] Molecular characterization of a carbapenem-hydrolyzing β-lactamase from Chryseobacterium (Flavobacterium) indologenes
    Bellais, S
    Léotard, S
    Poirel, L
    Naas, T
    Nordmann, P
    [J]. FEMS MICROBIOLOGY LETTERS, 1999, 171 (02) : 127 - 132
  • [7] Carbapenems in clinical practice: a guide to their use in serious infection
    Bradley, JS
    Garau, J
    Lode, H
    Rolston, KVI
    Wilson, SE
    Quinn, JP
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 1999, 11 (02) : 93 - 100
  • [8] Metallo-β-lactamases:: A class apart
    Bush, K
    [J]. CLINICAL INFECTIOUS DISEASES, 1998, 27 : S48 - S53
  • [9] IMP-4, a novel metallo-β-lactamase from nosocomial Acinetobacter spp. collected in Hong Kong between 1994 and 1998
    Chu, YW
    Afzal-Shah, M
    Houang, ETS
    Palepou, MFI
    Lyon, DJ
    Woodford, N
    Livermore, DM
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2001, 45 (03) : 710 - 714
  • [10] Detection of extended-spectrum beta-lactamase (ESBL)-producing strains by the Etest ESBL screen
    Cormican, MG
    Marshall, SA
    Jones, RN
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (08) : 1880 - 1884