Chronological changes of serum chromium levels after modern metal-on-metal total hip arthroplasty

被引:16
作者
Maezawa, K [1 ]
Nozawa, M [1 ]
Matsuda, K [1 ]
Yasuma, M [1 ]
Mori, K [1 ]
Enomoto, F [1 ]
Ogawa, S [1 ]
Shitoto, K [1 ]
Kurosawa, H [1 ]
机构
[1] Juntendo Univ, Sch Med, Dept Orthopaed Surg, Bunkyo Ku, Tokyo 1138421, Japan
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 2004年 / 75卷 / 04期
关键词
D O I
10.1080/00016470410001187-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We determined changes in serum chromium concentration every 6 months up to 3 years after implantation in 44 patients (mean age 63 (49-79) years, 35 women) who underwent modern metal-on-metal total hip arthroplasty (Metasul). The serum chromium levels increased between the first and second year after implantation (1 year: 1.05 (SD 0.76) mug/L, 2 years: 1.46 (SD 0.91) mug/L). A small increase was observed during the third year (1.61 (SD 1.31) mug/L). The clinical relevance of this finding is uncertain and should be determined in long-term studies on a large scale.
引用
收藏
页码:422 / 426
页数:5
相关论文
共 23 条
[1]
AMSTUTZ HC, 1996, CLIN ORTHOP S, V329, pS11
[2]
Elevated serum cobalt with metal-on-metal articulating surfaces [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
GottsaunerWolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02) :316-321
[3]
WIDESPREAD DISSEMINATION OF METAL DEBRIS FROM IMPLANTS [J].
CASE, CP ;
LANGKAMER, VG ;
JAMES, C ;
PALMER, MR ;
KEMP, AJ ;
HEAP, PF ;
SOLOMON, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :701-712
[4]
DANDY DJ, 1975, J BONE JOINT SURG BR, VB 57, P30, DOI 10.1302/0301-620X.57B1.30
[5]
DOORN PF, 1996, CLIN ORTHOP S, V329, pS187
[6]
DORR LD, 1990, CLIN ORTHOP RELAT R, P82
[7]
Total hip arthroplasty with use of the metasul metal-on-metal articulation - Four to seven-year results [J].
Dorr, LD ;
Wang, ZI ;
Longjohn, DB ;
Dubois, B ;
Murken, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (06) :789-798
[8]
Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro [J].
Green, TR ;
Fisher, J ;
Stone, M ;
Wroblewski, BM ;
Ingham, E .
BIOMATERIALS, 1998, 19 (24) :2297-2302
[9]
Metal release in patients who have has a primary total hip arthroplasty - A prospective, controlled, longitudinal study [J].
Jacobs, JJ ;
Skipor, AK ;
Patteson, LM ;
Hallab, NJ ;
Paprosky, WG ;
Black, J ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (10) :1447-1458
[10]
JACOBS JJ, 1995, CLIN ORTHOP RELAT R, P94