摘要
This paper reports a new relative humidity (RH) sensor for monitoring operating environment of a radio frequency (RF) system. The proposed RH sensor is based on two different microwave resonators in its structure, a coplanar waveguide (CPW)-to-slotline ring resonator and a microstrip patch antenna, and a customized polyimide film for humidity sensing material. To integrate a humidity sensor without making a RF system complex, first harmonic resonant frequency of the resonators are designed to be 3.375 and 5.0 GHz for the CPW-to-slotline ring resonator and the microstrip patch antenna, respectively. For high sensitivity of the polyimide film to RH change, it was synthesized from oxidianiline (ODA), m-pyromellitic dianhydride (m-PMDA), and N-methly-2-pyrrolidone (NMP) in which any hydrophobic elements are not included. This results in enhancement of water sorption characteristic of the polyimide film which serves as a dielectric layer of the microwave resonators. Calibration of the microwave RH sensors was carried out in terms of sensitivity, hysteresis and stability. These characteristics were analyzed through change in first harmonic resonant frequency of the resonators against various RH levels. Sensitivity of the RH sensor using the CPW-to-slotline ring resonator was -181 kHz/%RH and 4.95 mdB/%RH in terms of its resonant frequency and insertion loss, respectively. Hysteresis was 0.0013%, and average-percent-deviation from an average resonant frequency was 0.002%. Sensitivity of the antenna RH sensor was -108 kHz/%RH and 5.50 mdB/%RH in terms of resonant frequency and return loss, respectively. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:315 / 322
页数:8
相关论文
共 17 条
[1]   ANALYSIS OF A MICROSTRIP COVERED WITH A LOSSY DIELECTRIC [J].
BAHL, IJ ;
STUCHLY, SS .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1980, 28 (02) :104-109
[2]  
CHEEKE JDN, 1996, P IEEE ULTR S, P449
[3]   A high-sensitivity polyimide capacitive relative humidity sensor for monitoring anodically bonded hermetic micropackages [J].
Dokmeci, M ;
Najafi, K .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2001, 10 (02) :197-204
[4]  
EDWARDS T, 1991, FDN MICROSTRIP CIRCU, P245
[5]   Water sorption and diffusion behaviours in thin films of photosensitive polyimides [J].
Han, H ;
Seo, J ;
Ree, M ;
Pyo, SM ;
Gryte, CC .
POLYMER, 1998, 39 (13) :2963-2972
[6]  
KANG U, 2000, IEEE T ELECT DECVICE, V47
[7]  
Kim Y.J, 1997, THESIS GEORGIA I TEC
[8]  
Kim YH, 2005, SENSOR MATER, V17, P139
[9]  
KIM YJ, 1998, IEEE T COMP PACKAG C, V21, P26
[10]   Comparison of Three Humidity Sensors for a Pulmonary Function Diagnosis Microsystem [J].
Laville, Celine ;
Pellet, Claude .
IEEE SENSORS JOURNAL, 2002, 2 (02) :96-101