Validity and reliability of three commercially available breath-by-breath respiratory systems

被引:125
作者
Carter, J [1 ]
Jeukendrup, AE [1 ]
机构
[1] Univ Birmingham, Sch Sport & Exercise Sci, Human Performance Lab, Birmingham B15 2TT, W Midlands, England
关键词
gas exchange; exercise testing; reproducibility; breath-by-breath measurements; on-line systems;
D O I
10.1007/s00421-001-0572-2
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Information concerning the validity and reliability of commercial on-line gas analysis systems is limited. The aim of this study was to provide a comparison of the validity and reliability of three on-line systems (Oxycon Alpha, Oxycon Pro and Pulmolab EX670) with that of Douglas bags. Two separate studies were conducted. In study 1, the three gas analysis systems were compared with Douglas bags using a metabolic simulator over four increases in ventilation. In study 2, ten subjects were split into equal groups exercising at 100 W or 150 W for 85 min on three separate occasions. Each system was used twice per visit. Study I demonstrated that the Oxycon Alpha and Douglas bags produced similar respiratory values over all levels of ventilation. The Oxycon Pro tended to slightly overestimate mean expiratory flow ((V) over dot (E)), oxygen uptake ((V) over dot O-2), carbon dioxide production ((V) over dot CO2) and respiratory exchange ratio (RER) at the higher ventilations The Pulmolab produced large overestimations at all ventilations for (V) over dot CO2 and RER (up to. 26.3% away from expectations), whilst values for (V) over dot (E), and (V) over dot O-2 were slightly underestimated at higher ventilations (up to 7.5% from expectations). The results of study 2 support the findings of study 1, with the Oxycon Pro and Oxycon Alpha producing. similar results compared to Douglas bags for (V) over dot O-2, (V) over dot CO2 and RER. The coefficients of variation for (V) over dot O-2 and (V) over dot CO2 measured using Douglas bags, Oxycon Pro and Oxycon Alpha were 3.3-5.1%, 4.7-7.0% and 4.5-6.3%, respectively, whilst that for the Pulmolab was highly variable (26.8-45.8%). The exercise study showed the Oxycon Pro and Oxycon Alpha to be both valid and reliable on-line systems for the measurement of parameters of respiration, at least at workloads up to 150 W.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 16 条
  • [1] VARIABILITY OF RESPIRATION AND METABOLISM - RESPONSES TO SUBMAXIMAL CYCLING AND RUNNING
    ARMSTRONG, LE
    COSTILL, DL
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1985, 56 (02) : 93 - 96
  • [2] Hausswirth C, 1997, INT J SPORTS MED, V18, P449
  • [3] DAY TO DAY VARIATION IN TIME TRIAL CYCLING PERFORMANCE
    HICKEY, MS
    COSTILL, DL
    MCCONELL, GK
    WIDRICK, JJ
    TANAKA, H
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1992, 13 (06) : 467 - 470
  • [4] Jensen K, 1998, SCAND J MED SCI SPOR, V8, P1
  • [5] BIOLOGICAL VARIABILITY IN MAXIMUM AEROBIC POWER
    KATCH, VL
    SADY, SS
    FREEDSON, P
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1982, 14 (01) : 21 - 25
  • [6] RELIABILITY OF MEASUREMENT OF OXYGEN-UPTAKE BY A PORTABLE TELEMETRIC SYSTEM
    KAWAKAMI, Y
    NOZAKI, D
    MATSUO, A
    FUKUNAGA, T
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1992, 65 (05): : 409 - 414
  • [7] VARIABILITY OF AEROBIC PERFORMANCE IN THE LABORATORY AND ITS PHYSIOLOGIC CORRELATES
    KUIPERS, H
    VERSTAPPEN, FTJ
    KEIZER, HA
    GEURTEN, P
    VANKRANENBURG, G
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1985, 6 (04) : 197 - 201
  • [8] KUIPERS H, 1983, THESIS U LIMBURG MAA
  • [9] VALIDITY AND RELIABILITY OF THE COSMED K2 TO MEASURE OXYGEN-UPTAKE
    LOTHIAN, F
    FARRALLY, MR
    MAHONEY, C
    [J]. CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 1993, 18 (02): : 197 - 206
  • [10] VALIDITY AND RELIABILITY OF THE COSMED K2 INSTRUMENT
    LUCIA, A
    FLECK, SJ
    GOTSHALL, RW
    KEARNEY, JT
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1993, 14 (07) : 380 - 386