Real time magnetic field and flux measurements for tokamak control using a multi-core PCI Express system

被引:12
作者
Giannone, L. [1 ]
Schneider, W. [1 ]
McCarthy, P. J. [3 ]
Sips, A. C. C. [1 ]
Treutterer, W. [1 ]
Behler, K. [1 ]
Eich, T. [1 ]
Fuchs, J. C. [1 ]
Hicks, N. [1 ]
Kallenbach, A. [1 ]
Maraschek, M. [1 ]
Mlynek, A. [1 ]
Neu, G. [1 ]
Pautasso, G. [1 ]
Raupp, G. [1 ]
Reich, M. [1 ]
Schuhbeck, K. H. [1 ]
Stober, J. [1 ]
Volpe, F. [1 ]
Zehetbauer, T. [1 ]
Cerna, M. [2 ]
Debelle, T. [2 ]
Marker, B. [2 ]
McCaslin, S. [2 ]
Munroe, M. [2 ]
Wenzel, L. [2 ]
机构
[1] IPP EURATOM Assoc, Max Planck Inst Plasmaphys, D-85748 Garching, Germany
[2] Natl Instruments Corp, Austin, TX 78759 USA
[3] Univ Coll Cork, Assoc EURATOM DCU, Dept Phys, Cork, Ireland
关键词
Magnetic probe; Flux loop; Function parameterisation; Real time flux surfaces; Tokamak equilibrium; Multi-core; PLASMA CONTROL-SYSTEM; ASDEX UPGRADE; MHD EQUILIBRIA; DIAGNOSTICS; JET;
D O I
10.1016/j.fusengdes.2008.12.059
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The existing real time system for the position and shape control in ASDEX Upgrade has been extended to calculate magnetic flux surfaces in real time using a multi-core PCI Express system running LabVIEW RT. The availability of reflective memory for LabVIEW RT will allow this system to be connected to the control system and other diagnostics in a multi-platform real time network. The measured response of each magnetic probe to the individual poloidal field coil Currents in the absence of plasma Current is compared to the calculated value. Prior to a tokamak discharge this comparison can be used to check for failure of the magnetic probe, flux loop or integrator. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:825 / 828
页数:4
相关论文
共 24 条
[1]   Manufacturing and commissioning of the new ex-vessel magnetic diagnostics system for JET [J].
Coccorese, V. ;
Artaserse, G. ;
Chitarin, G. ;
Edlington, T. ;
Gerasimov, S. ;
Peruzzo, S. ;
Quercia, A. ;
Sowden, C. .
FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) :1348-1358
[2]   Real-time acquisition and remote monitoring of steady state tokamak (SST-1) diagnostics data [J].
Dey, Manika ;
Pujara, H. D. .
FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) :1198-1202
[3]  
FERRON JR, 1997, P 24 EUR C CONTR FUS, P1125
[4]   Prototype of a radiation hard resistive bolometer for ITER [J].
Giannone, L ;
Queen, D ;
Hellman, F ;
Fuchs, JC .
PLASMA PHYSICS AND CONTROLLED FUSION, 2005, 47 (12) :2123-2143
[5]  
Jackson J.D., 1999, Classical Electrodynamics, V3rd, P142
[6]   Design concepts for KSTAR plasma control system [J].
Jhang, H ;
Choi, IS .
FUSION ENGINEERING AND DESIGN, 2005, 73 (01) :35-49
[7]   Status and prospect of JT-60 plasma control and diagnostic data processing systems for advanced operation scenarios [J].
Kurihara, K. ;
Yonekawa, I. ;
Kawamata, Y. ;
Sueoka, M. ;
Hosoyama, H. ;
Sakata, S. ;
Ohshima, T. ;
Sato, M. ;
Kiyono, K. ;
Ozeki, T. .
FUSION ENGINEERING AND DESIGN, 2006, 81 (15-17) :1729-1734
[8]   COMPUTATION OF IDEAL MHD EQUILIBRIA [J].
LACKNER, K .
COMPUTER PHYSICS COMMUNICATIONS, 1976, 12 (01) :33-44
[9]   Real-time communication for distributed plasma control systems [J].
Luchetta, A. ;
Barbalace, A. ;
Manduchi, G. ;
Soppelsa, A. ;
Taliercio, C. .
FUSION ENGINEERING AND DESIGN, 2008, 83 (2-3) :520-524
[10]   Analytical solutions to the Grad-Shafranov equation for tokamak equilibrium with dissimilar source functions [J].
Mc Carthy, PJ .
PHYSICS OF PLASMAS, 1999, 6 (09) :3554-3560