Dynamic contrast-enhanced myocardial perfusion imaging using saturation-prepared TrueFISP

被引:95
作者
Schreiber, WG [1 ]
Schmitt, M [1 ]
Kalden, P [1 ]
Mohrs, OK [1 ]
Kreitner, KF [1 ]
Thelen, M [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
关键词
perfusion; myocardium; magnetic resonance imaging; TrueFISP; ultrafast imaging;
D O I
10.1002/jmri.10209
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and test a saturation-recovery True-FISP (SR-TrueFISP) pulse sequence for first pass myocardial perfusion imaging. Materials and Methods: First-pass magnetic resonance imaging (MRI) of Gd-DTPA (2 ml) kinetics in the heart was performed using an SR-TrueFISP pulse sequence ITR/TE/alpha = 2.6 msec/1.4 msec/55degrees) with saturation preparation TD = 30 msec before the TrueFISP readout. Measurements were also performed with a conventional saturation-recovery TurboFLASH (SRTF) pulse sequence for comparison. Results: SR-TrueFISP images were of excellent quality and demonstrated contrast agent wash-in more clearly than SRTF images. The signal increase in myocardium was higher in SR-TrueFISP than in SRTF data. Precontrast SNR and peak CNR were not significantly different between both sequences despite 57% improved spatial resolution for SR-TrueFISP. Conclusion: SR-TrueFISP first-pass MRI of myocardial perfusion leads to a substantial improvement of image quality and spatial resolution. It is well suited for first-pass myocardial perfusion studies at cardiovascular MR systems with improved gradient hardware.
引用
收藏
页码:641 / 652
页数:12
相关论文
共 41 条
[1]   SUSCEPTIBILITY CHANGES FOLLOWING BOLUS INJECTIONS [J].
ALBERT, MS ;
HUANG, W ;
LEE, JH ;
PATLAK, CS ;
SPRINGER, CS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) :700-708
[2]   APPLICATIONS OF LAGGED NORMAL DENSITY CURVE AS A MODEL FOR ARTERIAL DILUTION CURVES [J].
BASSINGT.JB ;
ACKERMAN, FH ;
WOOD, EH .
CIRCULATION RESEARCH, 1966, 18 (04) :398-&
[3]   STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE [J].
CARR, HY .
PHYSICAL REVIEW, 1958, 112 (05) :1693-1701
[4]   A myocardial perfusion reserve index in humans using first-pass contrast-enhanced magnetic resonance imaging [J].
Cullen, JHS ;
Horsfield, MA ;
Reek, CR ;
Cherryman, GR ;
Barnett, DB ;
Samani, NJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (05) :1386-1394
[5]  
Deimling M., 1994, PROC 2 ANN M SMR SAN, P495
[6]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[7]   Improving MR quantification of regional blood volume with intravascular T-1 contrast agents: Accuracy, precision, and water exchange [J].
Donahue, KM ;
Weisskoff, RM ;
Chesler, DA ;
Kwong, KK ;
Bogdanov, AA ;
Mandeville, JB ;
Rosen, BR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :858-867
[8]  
DRAPER NR, 1998, APPL REGRESSION ANAL, P57
[9]   CONTRAST-ENHANCED ECHO-PLANAR MR-IMAGING OF MYOCARDIAL PERFUSION - PRELIMINARY-STUDY IN HUMANS [J].
EDELMAN, RR ;
LI, W .
RADIOLOGY, 1994, 190 (03) :771-777
[10]  
Haacke E M., 1999, MAGNETIC RESONANCE I, P451