Variability of measurement of glenoid version on computed tomography scan

被引:126
作者
Bokor, DJ
O'Sullivan, MD
Hazan, GJ
机构
[1] Western Sydney Orthopaed Associates, Parramatta, NSW 2076, Australia
[2] Hills Private Hosp, Parramatta, NSW, Australia
关键词
D O I
10.1016/S1058-2746(99)90096-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the study was to determine the variability of measurement that might occur with rotation of the scapula in the coronal plane when computed tomography scanning is used Ten dry scapula specimens had 4 sets of computed tomography scans performed at +20 degrees + 10 degrees, neutral, and - 10 degrees of scapula rotation. The angle of glenoid version was then measured according to the technique of Friedman. The measured value For glenoid version was noted to vary by as much as 10 degrees on the same specimen with minor rotation of the scapula. This result occurred because of differences in the curvature of the vertebral border of the scapula. The measured angle of glenoid version was most likely to vary with rotation of the scapula 10 degrees downward (ie, glenoid articular surface facing 10 degrees upward). For accurate and reproducible measurement of the glenoid version, it is essential that in the scout view the glenoid orientation is neutral (ie, glenoid surface is perpendicular to the plane of the computed tomography cut).
引用
收藏
页码:595 / 598
页数:4
相关论文
共 7 条
[1]   EXCESSIVE RETROVERSION OF THE GLENOID CAVITY - A CAUSE OF NONTRAUMATIC POSTERIOR INSTABILITY OF THE SHOULDER [J].
BREWER, BJ ;
WUBBEN, RC ;
CARRERA, GF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (05) :724-731
[2]   COMPLEX FRACTURES OF THE PROXIMAL HUMERUS - ROLE OF CT IN TREATMENT [J].
CASTAGNO, AA ;
SHUMAN, WP ;
KILCOYNE, RF ;
HAYNOR, DR ;
MORRIS, ME ;
MATSEN, FA .
RADIOLOGY, 1987, 165 (03) :759-762
[3]  
CYPRIEN JM, 1983, CLIN ORTHOP RELAT R, V175, P8
[4]  
DAS S. P., 1966, J ANAT SOC INDIA, V15, P114
[5]   THE USE OF COMPUTERIZED-TOMOGRAPHY IN THE MEASUREMENT OF GLENOID VERSION [J].
FRIEDMAN, RJ ;
HAWTHORNE, KB ;
GENEZ, BM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1032-1037
[6]  
RANDELLI M, 1986, CLIN ORTHOP RELAT R, V208, P151
[7]   DYNAMIC STABILITY OF GLENOHUMERAL JOINT [J].
SAHA, AK .
ACTA ORTHOPAEDICA SCANDINAVICA, 1971, 42 (06) :491-+