Renal resistive index and nocturnal non-dipping: Is there an association in essential hypertension?

被引:8
作者
Afsar, Baris [1 ]
Ozdemir, Nurhan F. [1 ]
Elsurer, Rengin [1 ]
Sezer, Siren [1 ]
机构
[1] Baskent Univ Hosp, Dept Nephrol, TR-06500 Ankara, Turkey
关键词
Doppler ultrasonography; Essential hypertension; Nocturnal non-dipping; Renal resistive index; MILD ESSENTIAL-HYPERTENSION; PRESSURE MEASURING DEVICES; BLOOD-PRESSURE; DOPPLER SONOGRAPHY; INTERNATIONAL-PROTOCOL; CARDIOVASCULAR RISK; ARTERIAL STIFFNESS; PULSE PRESSURE; DISEASE; MORTALITY;
D O I
10.1007/s11255-008-9455-3
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Renal Doppler ultrasonography (RDU) is a useful method to determine renal resistive index (RRI). The RRI has been used to evaluate target organ damage (TOD) in essential hypertension. Nocturnal non-dipping of blood pressure (BP) in essential hypertension was also associated with TOD. The relationship between increased RRI and non-dipping has not been specifically studied before. Patients with newly diagnosed essential hypertension underwent 24-h ambulatory BP monitoring, biochemistry analysis, 24-h urine testing, and RDU. Totally, 198 patients (137 women, 61 men, aged 53.8 +/- A 11.4 years) were included. Sixty-two patients were non-dippers, and 56 patients had increased RRI. RRI was increased in 32.3% of non-dipper patients and in 26.5% of dipper patients (P = 0.402). The RRIs of dippers were lower than the RRIs of non-dippers (0.65 +/- A 0.06 vs. 0.68 +/- A 0.07, P = 0.036). Multivariate logistic regression analysis of potential factors predicting increased RRI disclosed that advanced age (OR 1.090, CI 1.042-1.140, P < 0.0001) and increased pulse pressure (OR 1.037, CI 1.012-1.062, P = 0.004) were independently associated with increased RRI. In multivariate linear regression analysis, using the same independent variables, we found that square root-transformed RRI was independently associated with age (Beta + 0.366, P < 0.0001) and pulse pressure (Beta + 0.222, P = 0.001). Increased RRI and nocturnal non-dipping are not independently associated with each other in newly diagnosed essential hypertensive patients. Possible different mechanisms, or the same mechanisms but with different activation levels, may be responsible for the increased RRI and non-dipping as discrete pathologies.
引用
收藏
页码:383 / 391
页数:9
相关论文
共 37 条
[1]   A decrease in diastolic blood pressure combined with an increase in systolic blood pressure is associated with a higher cardiovascular mortality in men [J].
Benetos, A ;
Zureik, M ;
Morcet, J ;
Thomas, F ;
Bean, K ;
Safar, M ;
Ducimetière, P ;
Guize, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (03) :673-680
[2]   Carotid arterial stiffness as a predictor of cardiovascular and all-cause mortality in end-stage renal disease [J].
Blacher, J ;
Pannier, B ;
Guerin, AP ;
Marchais, SJ ;
Safar, ME ;
London, GM .
HYPERTENSION, 1998, 32 (03) :570-574
[3]   Isolated systolic hypertension - Prognostic information provided by pulse pressure [J].
Domanski, MJ ;
Davis, BR ;
Pfeffer, MA ;
Kastantin, M ;
Mitchell, GF .
HYPERTENSION, 1999, 34 (03) :375-380
[4]  
Ebata H, 1995, Hypertens Res, V18, P125, DOI 10.1291/hypres.18.125
[5]   Renal artery stenosis and accelerated atherosclerosis: which comes first? [J].
Fava, Cristiano ;
Minuz, Pietro ;
Patrignani, Paola ;
Morganti, Alberto .
JOURNAL OF HYPERTENSION, 2006, 24 (09) :1687-1696
[6]   Is pulse pressure useful in predicting risk for coronary heart disease? The Framingham Heart Study [J].
Franklin, SS ;
Khan, SA ;
Wong, ND ;
Larson, MG ;
Levy, D .
CIRCULATION, 1999, 100 (04) :354-360
[7]  
Gavin JR, 1997, DIABETES CARE, V20, P1183
[8]   MICROALBUMINURIA AND CASUAL AND AMBULATORY BLOOD-PRESSURE MONITORING IN NORMOTENSIVES AND IN PATIENTS WITH BORDERLINE AND MILD ESSENTIAL-HYPERTENSION [J].
GIACONI, S ;
LEVANTI, C ;
FOMMEI, E ;
INNOCENTI, F ;
SEGHIERI, G ;
PALLA, L ;
PALOMBO, C ;
GHIONE, S .
AMERICAN JOURNAL OF HYPERTENSION, 1989, 2 (04) :259-261
[9]  
JENSEN G, 1994, J HYPERTENS, V12, P959
[10]   Validation of the OSCAR 2 oscillometric 24-hour ambulatory blood pressure monitor according to the International Protocol for the validation of blood pressure measuring devices [J].
Jones, SC ;
Bilous, M ;
Winship, S ;
Finn, P ;
Goodwin, J .
BLOOD PRESSURE MONITORING, 2004, 9 (04) :219-223