A new rapid point-of-care D-dimer enzyme-linked immunosorbent assay (Stratus CS D-dimer) for the exclusion of venous thromboembolism

被引:15
作者
Reber, G [1 ]
Bounameaux, H
Perrier, A
de Moerloose, P
机构
[1] Univ Hosp Geneva, Div Angiol & Haemostasis, Haemostasis Unit, CH-1211 Geneva 14, Switzerland
[2] Univ Hosp Geneva, Dept Internal Med, CH-1211 Geneva 14, Switzerland
关键词
D-dimer; venous thromboembolism; enzyme-linked immunosorbent assay;
D O I
10.1097/01.mbc.0000114443.59147.c4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the performances of a new D-dimer assay, Stratus CS D-dimer (Dade Behring, Newark, Delaware, USA), for the exclusion of venous thromboembolism and to determine the best cut-off values. This test relies on a sandwich enzyme-linked immunosorbent assay with a fluorogenic substrate in a radial partition immunoassay system in a dedicated device. It does not require laboratory staff and the results are available within 18 min. Two hundred and ninety-one frozen samples from patients suspected of either deep various thrombosis (n = 137) or pulmonary embolism (n = 154) were measured and the results compared with the VIDAS D-dimer New assay. There were 37 deep venous thrombosis (27%) and 49 pulmonary embolism (32%) samples. Receiver-operating characteristic curve analysis indicated that the cut-off value could be set at either 300 or 400 ng/ml Fibrinogen Equivalent Units (FEU). The coefficient of variation determined with a lyophilized low-level control plasma (305 ng/ml FEU) was 6%. With a cut-off at 300 ng/ml FEU, the sensitivity, the specificity and the negative predictive value were 100% [95% confidence interval (CI), 95.8-100], 33.1% (95% CI, 26.8-40) and 100% (95% CI, 94.7-100), respectively. Raising the cut-off to 400 ng/ml FEU, the corresponding figures were 96.5% (95% CI, 90.1-99.3), 46.3% (95% CI, 39.4-53.2) and 96.9% (95% CI, 91.3-99.4), respectively. At 400 ng/ml, three results were false-negative, one with both devices and two with the Stratus D-dimer only. Stratus D-dimer appears to be suitable for the exclusion of venous thromboembolism in the emergency room setting. (C) 2004 Lippincott Williams Wilkins.
引用
收藏
页码:435 / 438
页数:4
相关论文
共 16 条
[1]   The accuracy of the enzyme-linked immunosorbent assay D-dimer test in the diagnosis of pulmonary embolism: A meta-analysis [J].
Brown, MD ;
Rowe, BH ;
Reeves, MJ ;
Bermingham, JM ;
Goldhaber, SZ .
ANNALS OF EMERGENCY MEDICINE, 2002, 40 (02) :133-144
[2]  
de Moerloose P, 2000, THROMB HAEMOSTASIS, V83, P180
[3]  
de Moerloose P, 2001, THROMB HAEMOSTASIS, V85, P185
[4]   Observer dependency of the simplified D-dimer assay in 81 consecutive patients with suspected pulmonary embolism [J].
de Monyé, W ;
Huisman, MV ;
Pattynama, PMT .
THROMBOSIS RESEARCH, 1999, 96 (04) :293-298
[5]   Multicentre evaluation of a new point-of-care test for the quantitative determination of D-dimer [J].
Dempfle, CE ;
Schraml, M ;
Besenthal, I ;
Hansen, R ;
Gehrke, J ;
Korte, W ;
Risch, M ;
Quehenberger, P ;
Handler, S ;
Minar, E ;
Schulz, I ;
Zerback, R .
CLINICA CHIMICA ACTA, 2001, 307 (1-2) :211-218
[6]   Use of D-dimer assays in the diagnosis of venous thrombosis [J].
Dempfle, CE .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2000, 26 (06) :631-641
[7]  
Freyburger G, 1998, THROMB HAEMOSTASIS, V79, P32
[8]   THE DETECTION OF D-DIMER IN PLASMA BY ENZYME-IMMUNOASSAY - IMPROVED DISCRIMINATION IS OBTAINED WITH A MORE SPECIFIC SIGNAL ANTIBODY [J].
HART, R ;
BATE, I ;
DINH, D ;
ELMS, M ;
BUNDESEN, P ;
HILLYARD, C ;
RYLATT, DB .
BLOOD COAGULATION & FIBRINOLYSIS, 1994, 5 (02) :227-232
[9]   Longitudinal stability of coagulation, fibrinolysis, and inflammation factors in stored plasma samples [J].
Lewis, MR ;
Callas, PW ;
Jenny, NS ;
Tracy, RP .
THROMBOSIS AND HAEMOSTASIS, 2001, 86 (06) :1495-1500
[10]  
Mac Gillavry MR, 2001, THROMB HAEMOSTASIS, V85, P995