Long-term biocompatibility of implanted polymer-based intrafascicular electrodes

被引:40
作者
Lawrence, SM
Larsen, JO
Horch, KW
Riso, R
Sinkjær, T
机构
[1] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[2] Univ Aarhus, Stereol Res Lab, Aarhus, Denmark
[3] Aalborg Hosp, Inst Pathol, Aalborg, Denmark
[4] Univ Aalborg, Ctr Sensory Motor Interact, Aalborg, Denmark
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2002年 / 63卷 / 05期
关键词
neuroprosthetics; biocompatibility; peripheral nerve; intrafascicular electrodes;
D O I
10.1002/jbm.10303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polymer-based longitudinal intrafascicular electrodes (polyLIFEs) were chronically implanted into the sciatic nerve of white New Zealand rabbits (n = 8) for a period of 6 months (hereafter referred to as the long-term group). The impact of the implantation procedure, as observed 6 months post surgery, was evaluated in a sham-treated control group (n=9). The contralateral sciatic nerve served as the control for each animal. Nerve-fiber counts, fiber diameters, and myelin thickness were estimated at the level of the implant site, 1.5 cm proximally, and 1.5 cm distally for both nerves in sham-treated and long-term groups. Implantation of polyLIFEs had no significant effect on fiber counts, nerve-fiber diameter, or myelin thickness. A slight increase in connective tissue in the vicinity of the implant site was evident in the long-term group, including a thin but dense capsule immediately surrounding the implanted electrode. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:501 / 506
页数:6
相关论文
共 67 条
[1]   HISTOLOGIC AND PHYSIOLOGIC EVALUATION OF ELECTRICALLY STIMULATED PERIPHERAL-NERVE - CONSIDERATIONS FOR THE SELECTION OF PARAMETERS [J].
AGNEW, WF ;
MCCREERY, DB ;
YUEN, TGH ;
BULLARA, LA .
ANNALS OF BIOMEDICAL ENGINEERING, 1989, 17 (01) :39-60
[2]  
[Anonymous], NEURAL PROSTHESES RE
[3]   ACUTE AND CHRONIC IMPLANTATION OF COILED WIRE INTRANEURAL ELECTRODES DURING CYCLICAL ELECTRICAL-STIMULATION [J].
BOWMAN, BR ;
ERICKSON, RC .
ANNALS OF BIOMEDICAL ENGINEERING, 1985, 13 (01) :75-93
[4]   DECADE OF EXPERIENCE WITH ELECTRONIC SIMULATION OF MICTURITION REFLEX [J].
BRADLEY, WE ;
TIMM, GW ;
CHOU, SN .
UROLOGIA INTERNATIONALIS, 1971, 26 (04) :283-+
[5]   IMPLANT TO EMPTY BLADDER OR CLOSE URETHRA [J].
BRINDLEY, GS .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1977, 40 (04) :358-369
[6]   SACRAL ANTERIOR ROOT STIMULATORS FOR BLADDER CONTROL IN PARAPLEGIA [J].
BRINDLEY, GS ;
POLKEY, CE ;
RUSHTON, DN .
PARAPLEGIA, 1982, 20 (06) :365-381
[7]   SACRAL ANTERIOR ROOT STIMULATORS FOR BLADDER CONTROL IN PARAPLEGIA - THE 1ST 50 CASES [J].
BRINDLEY, GS ;
POLKEY, CE ;
RUSHTON, DN ;
CARDOZO, L .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1986, 49 (10) :1104-1114
[8]  
BRINDLEY GS, 1972, J PHYSIOL-LONDON, V222, pP135
[9]  
Burton C, 1975, Med Instrum, V9, P221
[10]  
Clippinger F., 1974, B PROSTHET RES, V10, P247