Enzyme-linked immunosorbent assays using recombinant envelope protein expressed in COS-1 and Drosophila S2 cells for detection of West Nile virus immunoglobulin m in serum or cerebrospinal fluid

被引:11
作者
Muerhoff, AS
Dawson, GJ
Dille, B
Gutierrez, R
Leary, TP
Gupta, MC
Kyrk, CR
Kapoor, H
Clark, P
Schochetman, G
Desai, SA
机构
[1] Abbott Labs, Infect Dis Res & Dev, Abbott Diagnost, Abbott Pk, IL 60064 USA
[2] Michigan Dept Community Hlth, Div Infect Dis, Bur Labs, Lansing, MI USA
关键词
D O I
10.1128/CDLI.11.4.651-657.2004
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Humans infected with West Nile virus (WNV) develop immunoglobulin M (IgM) antibodies soon after infection. The microtiter-based assays for WNV IgM antibody detection used by most state public health and reference laboratories utilize WNV antigen isolated from infected Vero cells or recombinant envelope protein produced in COS-1 cells. Recombinant antigen produced in COS-1 cells was used to develop a WNV IgM capture enzyme immunoassay (EIA). A supplementary EIA using WNV envelope protein expressed in Drosophila melanogaster S2 cells was also developed. Both assays detected WNV IgM in the sera of experimentally infected rhesus monkeys within approximately 10 days postinfection. Human sera previously tested for WNV IgM at a state public health laboratory (SPHL) were evaluated using both EIAs. Among the sera from 20 individuals with laboratory-confirmed WNV infection (i.e., IgM-positive cerebrospinal fluid [CSF]) that were categorized as equivocal for WNV IgM at the SPHL, 19 were IgM positive and one was negative by the new EIAs. Of the 19 IgM-positive patients, 15 were diagnosed with meningitis or encephalitis; the IgM-negative patient was not diagnosed with neurological disease. There was 100% agreement between the EIAs for the detection of WNV IgM. CSF samples from 21 individuals tested equivocal for WNV IgM at the SPHL; all 21 were positive in both bead assays, and 16 of these patients were diagnosed with neurological disease. These findings demonstrate that the new EIAs accurately identify WNV infection in individuals with confirmed WNV encephalitis and that they exhibit enhanced sensitivity over that of the microtiter assay format.
引用
收藏
页码:651 / 657
页数:7
相关论文
共 16 条
[1]  
Beaty BJCC, 1995, DIAGNOSTIC PROCEDURE
[2]   SERODIAGNOSIS OF LA-CROSSE VIRUS-INFECTIONS IN HUMANS BY DETECTION OF IMMUNOGLOBULIN-M CLASS ANTIBODIES [J].
CALISHER, CH ;
PRETZMAN, CI ;
MUTH, DJ ;
PARSONS, MA ;
PETERSON, ED .
JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 23 (04) :667-671
[3]   MEDICALLY IMPORTANT ARBOVIRUSES OF THE UNITED-STATES AND CANADA [J].
CALISHER, CH .
CLINICAL MICROBIOLOGY REVIEWS, 1994, 7 (01) :89-116
[4]  
Centers for Disease Control and Prevention (CDC), 1999, MMWR Morb Mortal Wkly Rep, V48, P845
[5]   REGULATED EXPRESSION ALLOWS HIGH-LEVEL PRODUCTION AND SECRETION OF HIV-1 GP120 ENVELOPE GLYCOPROTEIN IN DROSOPHILA SCHNEIDER CELLS [J].
CULP, JS ;
JOHANSEN, H ;
HELLMIG, B ;
BECK, J ;
MATTHEWS, TJ ;
DELERS, A ;
ROSENBERG, M .
BIO-TECHNOLOGY, 1991, 9 (02) :173-177
[6]   West Nile virus recombinant DNA vaccine protects mouse and horse from virus challenge and expresses in vitro a noninfectious recombinant antigen that can be used in enzyme-linked immunosorbent assays [J].
Davis, BS ;
Chang, GJJ ;
Cropp, B ;
Roehrig, JT ;
Martin, DA ;
Mitchell, CJ ;
Bowen, R ;
Bunning, ML .
JOURNAL OF VIROLOGY, 2001, 75 (09) :4040-4047
[7]   ELISA for detection of antibody to the E2 protein of GB virus C [J].
Gutierrez, RA ;
Dawson, GJ ;
Mushahwar, IK .
JOURNAL OF VIROLOGICAL METHODS, 1997, 69 (1-2) :1-6
[8]   A recombinant particulate antigen of Japanese encephalitis virus produced in stably-transformed cells is an effective noninfectious antigen and subunit immunogen [J].
Hunt, AR ;
Cropp, CB ;
Chang, GJJ .
JOURNAL OF VIROLOGICAL METHODS, 2001, 97 (1-2) :133-149
[9]   REGULATED EXPRESSION AT HIGH COPY NUMBER ALLOWS PRODUCTION OF A GROWTH-INHIBITORY ONCOGENE PRODUCT IN DROSOPHILA SCHNEIDER CELLS [J].
JOHANSEN, H ;
VANDERSTRATEN, A ;
SWEET, R ;
OTTO, E ;
MARONI, G ;
ROSENBERG, M .
GENES & DEVELOPMENT, 1989, 3 (06) :882-889
[10]   Standardization of immunoglobulin M capture enzyme-linked immunosorbent assays for routine diagnosis of arboviral infections [J].
Martin, DA ;
Muth, DA ;
Brown, T ;
Johnson, AJ ;
Karabatsos, N ;
Roehrig, JT .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) :1823-1826