Simultaneous determination of the herbicides diquat and paraquat in water

被引:45
作者
Rial-Otero, Raquel
Cancho-Grande, Beatriz
Perez-Lamela, Concepcion
Simal-Gandara, Jesus
Arias-Estevez, Manuel
机构
[1] Univ Vigo, Fac Food Sci & Technol, Analyt & Food Chem Dept, Nutr & Bromatol Grp, E-32004 Orense, Spain
[2] Univ Vigo, Fac Food Sci & Technol, Plant Biol & Soil Sci Dept, Soil & Agr Sci Grp, E-32004 Orense, Spain
关键词
D O I
10.1093/chromsci/44.9.539
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method based on solid-phase extraction (on silica cartridges) and high-performance liquid chromatography (HPLC) followed by diode array UV detection is presented as an analytical tool for screening diquat (DQ) and paraquat (PQ) in drinking waters. The method is useful for quality control laboratories of water companies and beverage industries. Absolute recoveries of DQ and PQ from drinking water (25 mL in all cases), spiked at levels between 0.1, 1.0, and 5.0 mu g/L, range from 91% to 103%. Relative standard deviation percentages are between 3% and 11%. Quantitation and detection limits are 70 and 40 ng/L for DQ and 90 and 60 ng/L for PQ, respectively; therefore, these herbicides can be detected and quantitated at levels below the limits established by the European Union.
引用
收藏
页码:539 / 542
页数:4
相关论文
共 23 条
[1]  
BARCELO D, 1993, ENV ANAL TECHNIQUES, P149
[2]   COMPARISON OF CAPILLARY ELECTROPHORESIS AND REVERSED-PHASE ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF PARAQUAT, DIQUAT AND DIFENZOQUAT [J].
CARNEIRO, MC ;
PUIGNOU, L ;
GALCERAN, MT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :217-224
[3]   Comparison of silica and porous graphitic carbon as solid-phase extraction materials for the analysis of cationic herbicides in water by liquid chromatography and capillary electrophoresis [J].
Carneiro, MC ;
Puignou, L ;
Galceran, MT .
ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) :263-269
[4]   Ion-pair liquid chromatography atmospheric pressure ionization mass spectrometry for the determination of quaternary ammonium herbicides [J].
Castro, R ;
Moyano, E ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 830 (01) :145-154
[5]   Determination of quaternary ammonium pesticides by liquid chromatography-electrospray tandem mass spectrometry [J].
Castro, R ;
Moyano, E ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 914 (1-2) :111-121
[6]   Ion-trap versus quadrupole for analysis of quaternary ammonium herbicides by LC-MS [J].
Castro, R ;
Moyano, E ;
Galceran, MT .
CHROMATOGRAPHIA, 2001, 53 (5-6) :273-278
[7]   On-line ion-pair solid-phase extraction-liquid chromatography-mass spectrometry for the analysis of quaternary ammonium herbicides [J].
Castro, R ;
Moyano, E ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :441-449
[8]  
CHICHILA TMP, 1993, J AOAC INT, V76, P1323
[9]   Separation of quaternary ammonium herbicides by capillary electrophoresis with indirect UV detection [J].
Galceran, MT ;
Carneiro, MC ;
Diez, M ;
Puignou, L .
JOURNAL OF CHROMATOGRAPHY A, 1997, 782 (02) :289-295
[10]   CAPILLARY ELECTROPHORESIS OF QUATERNARY AMMONIUM ION HERBICIDES - PARAQUAT, DIQUAT AND DIFENZOQUAT [J].
GALCERAN, MT ;
CARNEIRO, MC ;
PUIGNOU, L .
CHROMATOGRAPHIA, 1994, 39 (9-10) :581-586