The potential impact of CT-MRI matching on tumor volume delineation in advanced head and neck cancer

被引:137
作者
Rasch, C [1 ]
Keus, R [1 ]
Pameijer, FA [1 ]
Koops, W [1 ]
deRu, V [1 ]
Muller, S [1 ]
Touw, A [1 ]
Bartelink, H [1 ]
vanHerk, M [1 ]
Lebesque, JV [1 ]
机构
[1] NETHERLANDS CANC INST,DEPT RADIOL,NL-1066 CX AMSTERDAM,NETHERLANDS
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1997年 / 39卷 / 04期
关键词
CT-MRI matching; tumor volume delineation; advanced head and neck cancer;
D O I
10.1016/S0360-3016(97)00465-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To study the potential impact of the combined use of CT and MRI scans on the Gross Tumor Volume (GTV) estimation and interobserver variation. Methods and Materials: Four observers outlined the GTV in six patients with advanced head and neck cancer on CT, axial MRI, and coronal or sagittal MRI, The MRI scans were subsequently matched to the CT scan, The interobserver and interscan set variation were assessed in three dimensions. Results: The mean CT derived volume was a factor of 1.3 larger than the mean axial MRI volume, The range in volumes was larger for the CT than for the axial MRI volumes in five of the six cases, The ratio of the scan set common (i.e., the volume common to all GTVs) and the scan set encompassing volume (i.e., the smallest volume encompassing all GTVs) was closer to one in MRI (0.3-0.6) than in CT (0.1-0.5), The rest volumes (i.e., the volume defined by one observer as GTV in one data set but not in the other data set) were never zero for CT vs. MRI nor for MRI vs, CT, In two cases the craniocaudal border was poorly recognized on the axial MRI but could be delineated with a good agreement between the observers in the coronal/sagittal MRI. Conclusions: MRI-derived GTVs are smaller and have less interobserver variation than CT-derived GTVs, CT and MRI are complementary in delineating the GTV, A coronal or sagittal MRI adds to a better GTV definition in the craniocaudal direction. (C) 1997 Elsevier Science Inc.
引用
收藏
页码:841 / 848
页数:8
相关论文
共 27 条
[1]   MAGNETIC-RESONANCE IMAGE-DIRECTED STEREOTAXIC NEUROSURGERY - USE OF IMAGE FUSION WITH COMPUTERIZED-TOMOGRAPHY TO ENHANCE SPATIAL ACCURACY [J].
ALEXANDER, E ;
KOOY, HM ;
VANHERK, M ;
SCHWARTZ, M ;
BARNES, PD ;
TARBELL, N ;
MULKERN, RV ;
HOLUPKA, EJ ;
LOEFFLER, JS .
JOURNAL OF NEUROSURGERY, 1995, 83 (02) :271-276
[2]   LOCALIZATION OF THE PROSTATIC APEX FOR RADIATION TREATMENT PLANNING [J].
ALGAN, O ;
HANKS, GE ;
SHAER, AH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (04) :925-930
[3]  
ANG KK, 1994, RADIOTHERAPY HEAD NE, P33
[4]  
[Anonymous], 1993, 50 ICRU
[5]   SETUP DEVIATIONS IN WEDGED PAIR IRRADIATION OF PAROTID-GLAND AND TONSILLAR TUMORS, MEASURED WITH AN ELECTRONIC PORTAL IMAGING DEVICE [J].
BEL, A ;
KEUS, R ;
VIJLBRIEF, RE ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (02) :153-159
[6]   PROTON THERAPY FOR CARCINOMA OF THE NASOPHARYNX - A STUDY IN COMPARATIVE TREATMENT PLANNING [J].
BROWN, AP ;
URIE, MM ;
CHISIN, R ;
SUIT, HD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (06) :1607-1614
[7]  
DILLON WP, 1991, SEMIN ONCOL, V18, P64
[8]  
Faillace-Akazawa Pamela, 1995, International Journal of Radiation Oncology Biology Physics, V32, P152, DOI 10.1016/0360-3016(95)97687-V
[9]   MRI TREATMENT PLANNING FOR CNS NEOPLASM - GRAPHIC DISPLAY OF TARGET VOLUME USING BOXED CURSOR [J].
FORTIER, GA ;
PELLITTERI, MR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (01) :179-182
[10]   INTEGRATION OF MAGNETIC-RESONANCE-IMAGING INTO RADIATION-THERAPY TREATMENT PLANNING .1. TECHNICAL CONSIDERATIONS [J].
FRAASS, BA ;
MCSHAN, DL ;
DIAZ, RF ;
TENHAKEN, RK ;
AISEN, A ;
GEBARSKI, S ;
GLAZER, G ;
LICHTER, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (12) :1897-1908