Generating synthesized computed tomography (CT) from cone-beam computed tomography (CBCT) using CycleGAN for adaptive radiation therapy

被引:249
作者
Liang, Xiao [1 ]
Chen, Liyuan [1 ]
Dan Nguyen [1 ]
Zhou, Zhiguo [1 ]
Gu, Xuejun [1 ]
Yang, Ming [1 ]
Wang, Jing [1 ]
Jiang, Steve [1 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Radiat Oncol, Med Artificial Intelligence & Automat Lab, Dallas, TX 75390 USA
关键词
CBCT; CT; conversion; scatter correction; deep learning; CycleGAN; SCATTER CORRECTION; NECK; HEAD; RADIOTHERAPY; ALGORITHM;
D O I
10.1088/1361-6560/ab22f9
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Throughout the course of delivering a radiation therapy treatment, which may take several weeks, a patient's anatomy may change drastically, and adaptive radiation therapy (ART) may be needed. Cone-beam computed tomography (CBCT), which is often available during the treatment process, can be used for both patient positioning and ART re-planning. However, due to the prominent amount of noise, artifacts, and inaccurate Hounsfield unit (HU) values, the dose calculation based on CBCT images could be inaccurate for treatment planning. One way to solve this problem is to convert CBCT images to more accurate synthesized CT (sCT) images. In this work, we have developed a cycle-consistent generative adversarial network framework (CycleGAN) to synthesize CT images from CBCT images. This model is capable of image-to-image translation using unpaired CT and CBCT images in an unsupervised learning setting. The sCT images generated from CBCT through this CycleGAN model are visually and quantitatively similar to real CT images with decreased mean absolute error (MAE) from 69.29 HU to 29.85 HU for head-and-neck (H&N) cancer patients. The dose distributions calculated on the sCT by CycleGAN demonstrated a higher accuracy than those on CBCT in a 3D gamma index analysis with increased gamma index pass rate from 86.92% to 96.26% under 1 mm/1% criteria, when using the deformed planning CT image (dpCT) as the reference. We also compared the CycleGAN model with other unsupervised learning methods, including deep convolutional generative adversarial networks (DCGAN) and progressive growing of GANs (PGGAN), and demonstrated that CycleGAN outperformed the other two models. A phantom study has been conducted to compare sCT with dpCT, and the increase of structural similarity index from 0.91 to 0.93 shows that CycleGAN performed better than DIR in terms of preserving anatomical accuracy.
引用
收藏
页数:13
相关论文
共 21 条
[1]
Abe T., 2017, Int. J. Med. Phys. Clin. Eng. Radiat. Oncol., V6, P361, DOI 10.4236/ijmpcero.2017.64032
[2]
[Anonymous], 2017, PROC CVPR IEEE, DOI DOI 10.1109/CVPR.2017.632
[3]
[Anonymous], LECT NOTES COMPUTER
[4]
Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system [J].
Barker, JL ;
Garden, AS ;
Ang, KK ;
O'Daniel, JC ;
Wang, H ;
Court, LE ;
Morrison, WH ;
Rosenthal, DI ;
Chao, KSC ;
Tucker, SL ;
Mohan, R ;
Dong, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04) :960-970
[5]
Gan Z, 2017, 31 ANN C NEURAL INFO, V30
[6]
Goodfellow IJ, 2014, ADV NEUR IN, V27, P2672, DOI DOI 10.1145/3422622
[7]
A deformable head and neck phantom with in-vivo dosimetry for adaptive radiotherapy quality assurance [J].
Graves, Yan Jiang ;
Smith, Arthur-Allen ;
Mcilvena, David ;
Manilay, Zherrina ;
Lai, Yuet Kong ;
Rice, Roger ;
Mell, Loren ;
Jia, Xun ;
Jiang, Steve B. ;
Cervino, Laura .
MEDICAL PHYSICS, 2015, 42 (04) :1490-1497
[8]
Karras T., 2017, 6 INT C LEARN REPR 6 INT C LEARN REPR, P1
[9]
elastix: A Toolbox for Intensity-Based Medical Image Registration [J].
Klein, Stefan ;
Staring, Marius ;
Murphy, Keelin ;
Viergever, Max A. ;
Pluim, Josien P. W. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) :196-205
[10]
Investigating deformable image registration and scatter correction for CBCT-based dose calculation in adaptive IMPT [J].
Kurz, Christopher ;
Kamp, Florian ;
Park, Yang-Kyun ;
Zoellner, Christoph ;
Rit, Simon ;
Hansen, David ;
Podesta, Mark ;
Sharp, Gregory C. ;
Li, Minglun ;
Reiner, Michael ;
Hofmaier, Jan ;
Neppl, Sebastian ;
Thieke, Christian ;
Nijhuis, Reinoud ;
Ganswindt, Ute ;
Belka, Claus ;
Winey, Brian A. ;
Parodi, Katia ;
Landry, Guillaume .
MEDICAL PHYSICS, 2016, 43 (10) :5635-5646