Flow index evaluation of 3-D volume flow images:: An in vivo and in vitro study

被引:27
作者
Dubiel, Mariusz
Hammid, Anissa
Breborowicz, Andrzej
Pietryga, Marek
Sladkevicius, Povilas
Olofsson, Per-Ake
Breborowicz, Grzegorz H.
Gudmundsson, Saemundur [1 ]
机构
[1] Malmo Univ Hosp, Dept Obstet & Gynecol, S-20502 Malmo, Sweden
[2] Univ Poznan, Sch Med Sci, Univ Hosp, Dept Perinatol & Gynecol, PL-60965 Poznan, Poland
[3] Lund Univ, S-22100 Lund, Sweden
关键词
3-D ultrasound; power Doppler; blood flow; uterine artery; fetus; Doppler; pregnancy; flow index;
D O I
10.1016/j.ultrasmedbio.2006.01.016
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Three-dimensional (3-D) ultrasound imaging has improved evaluation of organ circulation and might contribute new information on maternal and fetal blood supply. Flow index (FI) of 3-D color images has been proposed as a measure of perfusion. The aim of this study was to evaluate whether the 3-D FI is a parameter of volume flow and flow velocity in a human vessel and in a flow phantom. A 1-cm-long strip of the uterine artery was recorded in 3-D power Doppler (3D-PD) mode in a cross-sectional study of 170 normal singleton pregnancies between 26 and 42 weeks' gestation. A fixed ultrasound system installation was used during the examination. The VOCAL (TM) software integrated in the ultrasound unit calculated vessel volume and FI. Reproducibility of the measurements was tested. The method was also tested on a commercially available flow phantom. Reproducibility measurements gave satisfactory results, both in terms of inter- and intraobserver variation. Unexpectedly, in normal pregnancy, the uterine artery FI decreased slightly with gestation. Uterine artery vessel volume increased, however, with gestational age. A poor correlation was found between the FI and both flow velocity and volume flow in the How phantom. In conclusion, 3D-PD imaging can give impressive anatomical pictures of organ vascular tree. However, the new FI is poorly related to flow velocity or volume of flow. (E-mail: saemundur.gudmundsson@med.lu.se) (c) 2006 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:665 / 671
页数:7
相关论文
共 22 条
[1]   MEASUREMENT OF UTERINE BLOOD FLOW AND UTERINE METABOLISM .8. UTERINE AND FETAL BLOOD FLOW AND OXYGEN CONSUMPTION IN EARLY HUMAN PREGNANCY [J].
ASSALI, NS ;
RAURAMO, L ;
PELTONEN, T .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1960, 79 (01) :86-98
[2]   COLOR DOPPLER IMAGING OF THE UTERINE ARTERY IN PREGNANCY - NORMAL RANGES OF IMPEDANCE TO BLOOD-FLOW, MEAN VELOCITY AND VOLUME OF FLOW [J].
BOWER, S ;
VYAS, S ;
CAMPBELL, S ;
NICOLAIDES, KH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1992, 2 (04) :261-265
[3]   PHYSIOLOGICAL RESPONSE OF VESSELS OF PLACENTAL BED TO NORMAL PREGNANCY [J].
BROSENS, I ;
ROBERTSON, WB ;
DIXON, HG .
JOURNAL OF PATHOLOGY AND BACTERIOLOGY, 1967, 93 (02) :569-+
[4]   Application of three-dimensional power Doppler ultrasound in prenatal diagnosis [J].
Chaoui, R ;
Kalache, KD ;
Hartung, J .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 17 (01) :22-29
[5]  
CHAOUI R, 1998, ULRASONOGRAPHY OBSTE, P135
[6]   Clinical utility of three-dimensional US [J].
Downey, DB ;
Fenster, A ;
Williams, JC .
RADIOGRAPHICS, 2000, 20 (02) :559-571
[7]   Computer analysis of three-dimensional power angiography images of foetal cerebral, lung and placental circulation in normal and high-risk pregnancy [J].
Dubiel, M ;
Breborowicz, GH ;
Ropacka, M ;
Pietryga, M ;
Maulik, D ;
Gudmundsson, S .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (03) :321-327
[8]  
Dubiel M, 1999, Eur J Ultrasound, V9, P223, DOI 10.1016/S0929-8266(99)00027-0
[9]   Betamethasone treatment and fetal lung perfusion evaluated with color Doppler energy imaging [J].
Dubiel, M ;
Gudmundsson, S ;
Pirhonen, J ;
Breborowicz, GH ;
Marsal, K .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1997, 10 (04) :272-276
[10]  
DUBIEL M, 2000, ARCH PERINATAL MED, V6, P37