An improved method for cyanide determination in blood using solid-phase microextraction and gas chromatography/mass spectrometry

被引:41
作者
Frison, Giampietro [1 ]
Zancanaro, Flavio [1 ]
Favretto, Donata [1 ]
Ferrara, Santo Davide [1 ]
机构
[1] Univ Hosp Padova, I-35121 Padua, Italy
关键词
D O I
10.1002/rcm.2689
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A new method is described for the qualitative and quantitative analysis of cyanide, a very short-acting and powerful toxic agent, in human whole blood. It involves the conversion of cyanide into hydrogen cyanide and its subsequent headspace solid-phase microextraction (HS-SPME) and detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode. Optimizing the conditions for the GC/MS (type of column, injection conditions, temperature program) and SPME (choice of SPME fiber, effect of salts, adsorption and desorption times, adsorption temperature) led to the choice of a 75-mu m carboxen/polydimethylsiloxane SPME fiber, with D-3-acetonitrile as internal standard, and a capillary GC column with a polar stationary phase. Method validation was carried out in terms of linearity, precision and accuracy in both aqueous solutions and blood. The limit of detection (LOD) and limit of quantitation (LOQ) were determined only in aqueous solutions. The assay is linear over three orders of magnitude (water 0.01-10, blood 0.05-10 mu g/mL); and the LOD and LOQ in water were 0.006 and 0.01 mu g/mL, respectively. Good intra- and inter-assay precision was obtained, always < 8%. The method is simple, fast and sensitive enough for the rapid diagnosis of cyanide intoxication in clinical and forensic toxicology. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:2932 / 2938
页数:7
相关论文
共 40 条
[1]
[Anonymous], 2004, TOX PROF CYAN
[2]
ELEVATED BLOOD CYANIDE CONCENTRATIONS IN VICTIMS OF SMOKE-INHALATION [J].
BAUD, FJ ;
BARRIOT, P ;
TOFFIS, V ;
RIOU, B ;
VICAUT, E ;
LECARPENTIER, Y ;
BOURDON, R ;
ASTIER, A ;
BISMUTH, C .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 325 (25) :1761-1766
[3]
Validation of liquid chromatographic and gas chromatographic methods - Applications to pharmacokinetics [J].
Bressolle, F ;
BrometPetit, M ;
Audran, M .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (01) :3-10
[4]
Rapid quantitation of cyanide in whole blood by automated headspace gas chromatography [J].
Calafat, AM ;
Stanfill, SB .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 772 (01) :131-137
[5]
Blood carbon monoxide and hydrogen cyanide concentrations in the fatalities of fire and non-fire associated civil aviation accidents, 1991-1998 [J].
Chaturvedi, AK ;
Smith, DR ;
Canfield, DV .
FORENSIC SCIENCE INTERNATIONAL, 2001, 121 (03) :183-188
[6]
Isotope dilution-mass spectrometry determination of blood cyanide by headspace gas chromatography [J].
Dumas, P ;
Gingras, G ;
LeBlanc, A .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (01) :71-75
[7]
Ellenhorn M. J., 1997, ELLENHORNS MED TOXIC, P1476
[8]
CYANIDE INGESTION - CASE-STUDIES OF 4 SUICIDES [J].
FERNANDO, GCA ;
BUSUTTIL, A .
AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 1991, 12 (03) :241-246
[9]
Detection of thiopental and pentobarbital in head and pubic hair in a case of drug-facilitated sexual assault [J].
Frison, G ;
Favretto, D ;
Tedeschi, L ;
Ferrara, SD .
FORENSIC SCIENCE INTERNATIONAL, 2003, 133 (1-2) :171-174
[10]
Determination of midazolam in human plasma by solid-phase microextraction and gas chromatography/mass spectrometry [J].
Frison, G ;
Tedeschi, L ;
Maietti, S ;
Ferrara, SD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (24) :2497-2501