Fused-silica-aperture thermospray sample introduction into axially viewed inductively coupled plasma-atomic emission spectrometry

被引:11
作者
Conver, TS
Yang, JF
Koropchak, JA
Shkolnik, G
FlajnikRivera, C
机构
[1] SO ILLINOIS UNIV,DEPT CHEM & BIOCHEM,CARBONDALE,IL 62901
[2] VARIAN ASSOCIATES INC,WOOD DALE,IL 60191
关键词
thermospray nebulization; axially viewed inductively coupled plasma-atomic emission spectrometry membrane desolvation;
D O I
10.1366/0003702971938786
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Axially viewed inductively coupled plasma-atomic emission spectrometry (ICP-AES) has encountered a resurgence in popularity over the past few years, It has been demonstrated that 5- to 10-fold improvements in limits of detection (LODs) can be obtained with axial viewing compared to conventional side-on-viewed ICP-AES. In this report, the coupling of fused-silica-aperture thermospray (FSApT)-based sample introduction with axially viewed ICP-AES is reported, in order to combine the properties of increased sample transport and reduced LODs for FSApT with the improved detection power of axially viewed ICP-AES. When FSApT was used with the standard axial torch having a large-diameter (2.3-mm) injector, high signal and background relative standard deviations (RSDs) resulted, as compared to results for pneumatic nebulization, limiting the LOD improvements obtained with FSApT. Smaller injectors (0.8-mm and 1.5-mm i.d.) allowed RSDs for FSApT that were similar to pneumatic sample introduction levels, and larger LOD improvements (10x) resulted. Data for FSApT with axially viewed ICP-AES were also compared with data for FSApT with side-on-viewed ICP-AES, and axial viewing averaged an improvement of only a factor of 2. This small level of improvement suggests that the optical system for the axial system is not optimized for use with high-performance sample introduction, On the basis of improvement factors for FSApT with side-on viewing, FSApT with axially viewed ICP-AES averages LODs that are about 73 times better than those for the conventional side-on-viewed ICP-AES with pneumatic nebulization.
引用
收藏
页码:68 / 73
页数:6
相关论文
共 13 条
[1]   SPECTROMETRIC STUDY ON RADIOFREQUENCY INDUCED PLASMA .1. ANALYTICAL PERFORMANCE [J].
ABDALLAH, MH ;
DIEMIASZONEK, R ;
JAROSZ, J ;
MERMET, JM ;
ROBIN, J ;
TRASSY, C .
ANALYTICA CHIMICA ACTA, 1976, 84 (02) :271-282
[2]   COMPARISON OF ULTRASONIC AND THERMOSPRAY SYSTEMS FOR HIGH-PERFORMANCE SAMPLE INTRODUCTION TO INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
CONVER, TS ;
KOROPCHAK, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (4-7) :341-354
[3]   AXIAL VIEW OF AN INDUCTIVELY COUPLED PLASMA [J].
DAVIES, J ;
DEAN, JR ;
SNOOK, RD .
ANALYST, 1985, 110 (05) :535-540
[4]   END-ON OBSERVATION OF A HORIZONTAL LOW-FLOW INDUCTIVELY COUPLED PLASMA [J].
DELOOSVOLLEBREGT, MTC ;
TIGGELMAN, JJ ;
DEGALAN, L .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (6-7) :773-781
[5]   THERMOSPRAY SAMPLE INTRODUCTION INTO A HORIZONTAL LOW-FLOW INDUCTIVELY COUPLED PLASMA WITH END-ON OBSERVATION [J].
DELOOSVOLLEBREGT, MTC ;
TIGGELMAN, JJ ;
BANK, PC ;
DEGRAEUWE, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (02) :213-217
[7]  
FAIRES LM, 1989, APPL SPECTROSC, V39, P5
[8]   PERFORMANCE EVALUATION OF AN AXIALLY VIEWED HORIZONTAL INDUCTIVELY-COUPLED PLASMA FOR OPTICAL-EMISSION SPECTROMETRY [J].
IVALDI, JC ;
TYSON, JF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (10) :1207-1226
[9]   FUSED-SILICA APERTURE THERMOSPRAY SAMPLE INTRODUCTION TO INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
KOROPCHAK, JA ;
VEBER, M ;
HERRIES, J .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (06) :825-834
[10]  
KOROPCHAK JA, 1992, APPL SPECTROSC, V46, P1525