Shear stress-induced apoptosis of adherent neutrophils: A mechanism for persistence of cardiovascular device infections

被引:59
作者
Shive, MS
Salloum, ML
Anderson, JM
机构
[1] Case Western Reserve Univ, Inst Pathol, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
关键词
D O I
10.1073/pnas.110463197
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The mechanisms underlying problematic cardiovascular device-associated infections are not understood. Because the outcome of the acute response to infection is largely dependent on the function of neutrophils, the persistence of these infections suggests that neutrophil function may be compromised because of cellular responses to shear stress. A rotating disk system was used to generate physiologically relevant shear stress levels (0-18 dynes/ cm(2); 1 dyne = 10 mu N) at the surface of a polyetherurethane urea film. We demonstrate that shear stress diminishes phagocytic ability in neutrophils adherent to a cardiovascular device material, and causes morphological and biochemical alterations that are consistent with those described for apoptosis. Complete neutrophil apoptosis occurred at shear stress levels above 6 dynes/cm(2) after only 1 h. Morphologically, these cells displayed irreversible cytoplasmic and nuclear condensation while maintaining intact membranes. Analysis of neutrophil area and filamentous actin content demonstrated concomitant decreases in both cell area and actin content with increasing levels of shear stress. Neutrophil phagocytosis of adherent bacteria decreased with increasing shear stress. Biochemical alterations included membrane phosphatidylserine exposure and DNA fragmentation, as evaluated by in situ annexin V and terminal deoxynucleotidyltransferase-mediated dUTP end labeling (TUNEL) assays, respectively. The potency of the shear-stress effect was emphasized by comparative inductive studies with adherent neutrophils under static conditions, The combination of tumor necrosis factor-or and cycloheximide was ineffective in inducing >21% apoptosis after 3 h. These findings suggest a mechanism through which shear stress plays an important role in the development of bacterial infections at the sites of cardiovascular device implantation.
引用
收藏
页码:6710 / 6715
页数:6
相关论文
共 59 条
[1]   COMPARISON OF THE RESISTANCE TO INFECTION OF INTESTINAL SUBMUCOSA ARTERIAL AUTOGRAFTS VERSUS POLYTETRAFLUOROETHYLENE ARTERIAL PROSTHESES IN A DOG-MODEL [J].
BADYLAK, SF ;
COFFEY, AC ;
LANTZ, GC ;
TACKER, WA ;
GEDDES, LA .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (03) :465-472
[2]   PROSTHETIC GRAFT INFECTION [J].
BANDYK, DF ;
ESSES, GE .
SURGICAL CLINICS OF NORTH AMERICA, 1994, 74 (03) :571-590
[3]   Cardiovascular applications of biomaterials and implants - An overview [J].
Black, MM .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1995, 19 (05) :151-157
[4]   EXPERIMENTAL FOREIGN-BODY INFECTIONS IN MICE CHALLENGED WITH SLIME-PRODUCING STAPHYLOCOCCUS-EPIDERMIDIS [J].
CHRISTENSEN, GD ;
SIMPSON, WA ;
BISNO, AL ;
BEACHEY, EH .
INFECTION AND IMMUNITY, 1983, 40 (01) :407-410
[5]   Cytoskeletal and adhesive structural polarizations accompany IL-13-induced human macrophage fusion [J].
DeFife, KM ;
Jenney, CR ;
Colton, E ;
Anderson, JM .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1999, 47 (01) :65-74
[6]  
DEWITZ TS, 1977, J LAB CLIN MED, V90, P728
[7]  
DEWITZ TS, 1979, BLOOD CELLS, V5, P499
[8]   Shear stress inhibits apoptosis of human endothelial cells [J].
Dimmeler, S ;
Haendeler, J ;
Rippmann, V ;
Nehls, M ;
Zeiher, AM .
FEBS LETTERS, 1996, 399 (1-2) :71-74
[9]   REGULATION OF CELL-ADHESION MOLECULE EXPRESSION AND FUNCTION-ASSOCIATED WITH NEUTROPHIL APOPTOSIS [J].
DRANSFIELD, I ;
STOCKS, SC ;
HASLETT, C .
BLOOD, 1995, 85 (11) :3264-3273
[10]  
ELEK SD, 1957, BRIT J EXP PATHOL, V38, P573