Corona ions from powerlines and increased exposure to pollutant aerosols

被引:79
作者
Fews, AP [1 ]
Henshaw, DL [1 ]
Wilding, RJ [1 ]
Keitch, PA [1 ]
机构
[1] Univ Bristol, HH Wills Phys Lab, Bristol BS8 1TL, Avon, England
关键词
D O I
10.1080/095530099139124
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To investigate corona ions emitted from high-voltage powerlines and assess their effects on exposure to environmental pollutant aerosols. Materials and methods: The charge density of ions in air required to produce a given change in the observed DC field at ground level was calculated. A DC field mill meter was used to map the DC fields near 132, 275 and 400 kV powerlines. Results: The Earth's natural DC field of around similar to 100 V m(-1) was significantly modified near powerlines in 8 out of 14 cases. Typically, downwind of the powerlines the field direction was reversed giving values to -340 V m(-1). In one case, the effect extended more than 500 m from a 275 kV line. Discussion: These results can be analysed in terms of the charge density present. This analysis suggests that typically 2000 excess negative charges per cm(3) are required to match the measured DC fields. Such space charge will result in unipolar aerosol charging in excess of the normal bipolar steady state charge distribution of pollutant aerosols. This may lead to increased lung deposition on inhalation.
引用
收藏
页码:1523 / 1531
页数:9
相关论文
共 29 条
[1]   A CHARGE SIMULATION-BASED METHOD FOR CALCULATING CORONA LOSS ON AC POWER TRANSMISSION-LINES [J].
ABDELSALAM, M ;
ABDELAZIZ, EZ .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1994, 27 (12) :2570-2579
[2]   ELECTROMAGNETIC-FIELDS AND CHILDHOOD-CANCER [J].
AHLBOM, A ;
FEYCHTING, M ;
KOSKENVUO, M ;
OLSEN, JH ;
PUKKALA, E ;
SCHULGEN, G ;
VERKASALO, P .
LANCET, 1993, 342 (8882) :1295-1296
[3]  
[Anonymous], 1999, NIH PUBL, V99-4493
[4]  
BORRA JP, 1995, P 12 INT S PLASM CHE, P1331
[5]   GROUND LEVEL ELECTRIC-FIELDS AND ION CURRENTS ON CELILO-SYLMAR +/-400 KV DC INTERTIE DURING FAIR WEATHER [J].
BRACKEN, TD ;
CAPON, AS ;
MONTGOMERY, DV .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (02) :370-378
[6]   EXPOSURE TO LEAD AND CADMIUM OF CHILDREN LIVING IN DIFFERENT AREAS OF NORTHWEST GERMANY - RESULTS OF BIOLOGICAL MONITORING STUDIES 1982-1986 [J].
BROCKHAUS, A ;
COLLET, W ;
DOLGNER, R ;
ENGELKE, R ;
EWERS, U ;
FREIER, I ;
JERMANN, E ;
KRAMER, U ;
MANOJLOVIC, N ;
TURFELD, M ;
WINNEKE, G .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1988, 60 (03) :211-222
[7]  
CHALMERS JA, 1952, J ATMOS TERR PHYS, V2, P155
[8]  
CHALMERS JA, 1967, ATMOSPHERIC ELECT, P175
[9]   Deposition of charged particles on lung airways [J].
Cohen, BS ;
Xiong, JQ ;
Fang, CP ;
Li, W .
HEALTH PHYSICS, 1998, 74 (05) :554-560
[10]   Increased exposure to pollutant aerosols under high voltage power lines [J].
Fews, AP ;
Henshaw, DL ;
Keitch, PA ;
Close, JJ ;
Wilding, RJ .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1999, 75 (12) :1505-1521