Five fully automated methods for performing immature reticulocyte fraction - Comparison in diagnosis of bone marrow aplasia

被引:29
作者
Buttarello, M
Bulian, P
Farina, G
Petris, MG
Temporin, V
Toffolo, L
机构
[1] Osped Geriat, Lab Patol Clin, I-35100 Padua, Italy
[2] Univ Padua, Dept Pediat, I-35100 Padua, Italy
关键词
automated analyzers; immature reticulocyte fraction; bone marrow aplasia;
D O I
10.1309/VJAA-L52P-FGRM-QGRU
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
We performed a parallel evaluation of 5 automated reticulocyte counters to produce the immature reticulocyte fraction (IRF). We analyzed 225 samples from healthy control subjects, 115 from, patients with various diseases, 38 with advanced aplasia, and 22 in early erythropoietic recovery after chemotherapy or bone marrow transplantation. The reference intervals were different for each instrument (ADVIA 120, 0.04-0.25; CELL DYN 4000, 0.15-0.35; GEN-S, 0.20-0.37; SE 9500 RET, 0.05-0.21; VEGA RETIC: 0.06-0.23). The imprecision, obtained by 1-way analysis of variance on duplicates, was satisfactory for clinical use for all methods (coefficient of variation, 7.6%-20.5% in healthy subjects), although it was higher than the analytic goal based on biologic variability within subjects. The comparison of different methods shows that agreement is good only between SE 9500 RET, CELL DYN 4000, and VEGA RETIC (r(2) = 0.72-0.78). The study of diagnostic performance in distinguishing aplasia from early bone marrow recovery shows slightly different results (area under the curve from 0.70 for ADVIA 120 to 0.96,for SE 9500 RET). Even with slight differences, the fluorescence-based methods seem to be more robust than other methods for IRF measurement.
引用
收藏
页码:871 / 879
页数:9
相关论文
共 27 条
[1]  
[Anonymous], 1997, LAB HEMATOL
[2]  
[Anonymous], LAB HEMATOL
[3]  
[Anonymous], 1944, ARCH BIOL
[4]  
AULESA C, 1994, EUR J HAEMATOL, V53, P293
[5]   Flow cytometric reticulocyte counting - Parallel evaluation of five fully automated analyzers: An NCCLS-ICSH approach [J].
Buttarello, M ;
Bulian, P ;
Farina, G ;
Temporin, V ;
Toffolo, L ;
Trabuio, E ;
Rizzotti, P .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2001, 115 (01) :100-111
[6]  
Buttarello M, 1995, ARCH PATHOL LAB MED, V119, P1141
[7]  
Chang CC, 1997, AM J CLIN PATHOL, V108, P69
[8]  
CHUNG KL, 1993, J CLIN LAB ANAL, V7, P371
[9]   Evaluation of the Abbott Cell Dyn 4000 automated fluorescent reticulocyte measurements:: comparison with manual, FACScan and Sysmex R1000 methods [J].
d'Onofrio, G ;
Kim, YR ;
Schulze, S ;
Lorentz, T ;
Dörner, K ;
Goossens, W ;
Zini, G ;
Tommasi, M ;
Kendall, R ;
Scott, CS .
CLINICAL AND LABORATORY HAEMATOLOGY, 1997, 19 (04) :253-260
[10]   FLOW CYTOMETRIC RETICULOCYTE ANALYSIS - MULTIINSTITUTIONAL INTERLABORATORY CORRELATION STUDY [J].
DAVIS, BH ;
BIGELOW, NC ;
KOEPKE, JA ;
BOROWITZ, MJ ;
HOUWEN, B ;
JACOBBERGER, JW ;
PIERRE, RV ;
CORASH, L ;
AULT, KA ;
BATJER, JD .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1994, 102 (04) :468-477