A parametric approach to measuring limbus corneae from digital images

被引:17
作者
Iskander, D. Robert [1 ]
机构
[1] Queensland Univ Technol, Contact Lens & Visual Opt Lab, Sch Optometry, Brisbane, Qld 4059, Australia
关键词
horizontal corneal diameter; horizontal visible iris diameter; limbus size; pupillometry; sigmoidal function; white-to-white corneal diameter;
D O I
10.1109/TBME.2006.873387
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
It is difficult to demarcate the limbus borders in standard intensity images of the eye since the transition from the cornea (iris) to sclera is gradual. Non-parametric techniques that are currently used for this task are not sufficiently precise to be adopted in those ophthalmic applications where high precision in determining the limbus/pupil characteristics is required. This is the case, for example, in customized refractive corrections. Another aspect of limbus corneae characterization is the inability of measuring in vivo the outer outline of the limbus annulus without specialized illumination techniques. To overcome these limitations, we propose a parametric approach that utilizes a sigmoidal function fitted to radial intensity profiles of the limbus corneae. By the way of simulations, we show the superiority of the proposed parametric approach when compared to an optimized nonparametric technique. Further, we review the techniques for fitting ellipses to the estimated points of the limbus annulus and discuss clinical aspects of the proposed methodology. Initial clinical experiments showed close agreement between the proposed approach and limbus corneae estimates manually obtained by experienced clinicians.
引用
收藏
页码:1134 / 1140
页数:7
相关论文
共 28 条
[1]
AHM SA, PATTERN RECOGNIT, V43, P2283
[2]
Algorithm for Purkinje images I and IV and limbus centre localization [J].
Barry, JC ;
Pongs, UM ;
Hillen, W .
COMPUTERS IN BIOLOGY AND MEDICINE, 1997, 27 (06) :515-531
[3]
Comparison of manual and automated methods to determine horizontal corneal diameter [J].
Baumeister, M ;
Terzi, E ;
Ekici, Y ;
Kohnen, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02) :374-380
[4]
Bueeler M, 2004, J REFRACT SURG, V20, P371
[5]
Maximum permissible lateral decentration in aberration-sensing and wavefront-guided corneal ablation [J].
Bueeler, M ;
Mrochen, M ;
Seiler, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (02) :257-263
[6]
A new approach to modelling sigmoidal curves [J].
Carrillo, M ;
Gonzalez, JM .
TECHNOLOGICAL FORECASTING AND SOCIAL CHANGE, 2002, 69 (03) :233-241
[7]
Donnenfeld E, 2004, J REFRACT SURG, V20, pS593
[8]
Douthwaite William A., 2002, CLAO Journal, V28, P202
[9]
Direct least square fitting of ellipses [J].
Fitzgibbon, A ;
Pilu, M ;
Fisher, RB .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1999, 21 (05) :476-480
[10]
Automatic pupillometry from digital images [J].
Iskander, DR ;
Collins, MJ ;
Mioschek, S ;
Trunk, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (09) :1619-1627