International comparisons of He-Ne lasers stabilized with 127I2 at λ≈633 nm (July 1993 to September 1995) Part IV:: Comparison of Western European lasers at λ≈633 nm

被引:17
作者
Darnedde, H
Rowley, WRC
Bertinetto, F
Millerioux, Y
Haitjema, H
Wetzels, S
Pirée, H
Prieto, E
Pérez, MM
Vaucher, B
Chartier, A
Chartier, JM
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
[2] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[3] Ist Metrol G Colonetti, I-10135 Turin, Italy
[4] Bur Natl Metrol, Inst Natl Metrol, Conservatoire Natl Art & Metiers, F-75141 Paris, France
[5] Nederlands Meetinst, NL-2600 AR Delft, Netherlands
[6] Gen Metrol, B-1040 Brussels, Belgium
[7] Ctr Espanol Metrol, Madrid 28760, Spain
[8] Off Fed Metrol, CH-3084 Wabern, Switzerland
[9] Bur Int Poids & Mesures, F-92312 Sevres, France
关键词
D O I
10.1088/0026-1394/36/3/5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper reports the fourth set of results of a series of grouped laser comparisons from national laboratories undertaken by the Bureau International des Poids et Mesures (BIPM) at the request of the Comite Consultatif pour la Definition du Metre (CCM; now the Consultative Committee for Length, CCL) during the period July 1993 to September 1995. The results of this comparison, involving eleven lasers from eight countries and the BIPM, again meet the goals set by the CCDM in 1992 and adopted by the Comite International des Poids et Mesures (CIPM) the same year. The standard uncertainty of the frequency of the He-Ne laser stabilized on the saturated absorption of I-127(2) at lambda approximate to 633 nm is reduced to a level of 12 kHz (2.5 parts in 10(11)) when the lasers compared meet the recommended values of the parameters. The lasers were first compared with the BIPM4 laser with the parameters set to the values normally used in each laboratory; using the BIPM4 laser as a reference the results ranged from -15.4 kHz to 36.8 kHz. After checking and readjusting the values of all the parameters, the range was reduced to -8.6 kHz to 14.0 kHz, Under the latter conditions, the average frequency difference of the group of lasers, with respect to the BIPM4 laser, was 2.7 kHz with a standard uncertainty (1 sigma) of 8.1 kHz. The best relative frequency stabilities, with Allan standard deviations of about 5.5 parts in 10(12) and 4.6 parts in 10(13), were observed with sampling times of 1 s and 100 s, respectively.
引用
收藏
页码:199 / 206
页数:8
相关论文
共 16 条
[1]   A CO2 TO VISIBLE OPTICAL FREQUENCY-SYNTHESIS CHAIN - ACCURATE MEASUREMENT OF THE 473 THZ HENE/I2 LASER [J].
ACEF, O ;
ZONDY, JJ ;
ABED, M ;
ROVERA, DG ;
GERARD, AH ;
CLAIRON, A ;
LAURENT, P ;
MILLERIOUX, Y ;
JUNCAR, P .
OPTICS COMMUNICATIONS, 1993, 97 (1-2) :29-34
[2]  
BAYERHELMS F, 1977, PTB ME, V17, P139
[3]   COMPARISON BETWEEN THE I-127(2) STABILIZED HE-NE LASERS AT 633 NM AND 612 NM OF THE BIPM AND THE IMGC [J].
BERTINETTO, F ;
CORDIALE, P ;
PICOTTO, GB ;
CHARTIER, JM ;
FELDER, R ;
GLASER, MG .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1983, 32 (01) :72-76
[4]   INTERNATIONAL COMPARISON OF IODINE CELLS [J].
CHARTIER, JM ;
PICARDFREDIN, S ;
CHARTIER, A .
METROLOGIA, 1992, 29 (05) :361-367
[5]   International comparisons of He-Ne lasers stabilized with 127I2 at λ≈633 nm (July 1993 to September 1995) Part I:: General [J].
Chartier, JM ;
Chartier, A .
METROLOGIA, 1997, 34 (04) :297-300
[6]   INTERNATIONAL INTERCOMPARISON OF WAVELENGTH OF IODINE-STABILIZED LASERS [J].
CHARTIER, JM ;
HELMCKE, J ;
WALLARD, AJ .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1976, 25 (04) :450-453
[7]   INTERCOMPARISON OF NORTHERN EUROPEAN I-127(2)-STABILIZED HE-NE LASERS AT LAMBDA = 633 NM [J].
CHARTIER, JM ;
DARNEDDE, H ;
FRENNBERG, M ;
HENNINGSEN, J ;
KARN, U ;
PENDRILL, L ;
HU, JP ;
PETERSEN, JC ;
POULSEN, O ;
RAMANUJAM, PS ;
RIEHLE, F ;
ROBERTSSON, L ;
STAHLBERG, B ;
WAHLGREN, H .
METROLOGIA, 1992, 29 (05) :331-339
[8]   Comparison between the He-Ne laser wavelength standards at 633 nm from the UME and the BIPM [J].
Erin, M ;
Malinovsky, I ;
Titov, A ;
Chartier, A ;
Chartier, JM .
METROLOGIA, 1996, 32 (05) :363-365
[9]   A STUDY OF CONTAMINATION IN I-127(2) CELLS USING LASER-INDUCED FLUORESCENCE [J].
FREDINPICARD, S .
METROLOGIA, 1989, 26 (04) :235-244
[10]   COMPARISON OF THE I-127(2) STABILIZED HE-NE LASERS AT 633NM WAVELENGTH OF THE NATIONAL-RESEARCH-LABORATORY-OF-METROLOGY OF JAPAN AND THE BUREAU-INTERNATIONAL-DES-POIDS-ET-MESURES [J].
IWASAKI, S ;
CHARTIER, JM .
METROLOGIA, 1989, 26 (04) :257-261