Time constant for water transport in loblolly pine trees estimated from time series of evaporative demand and stem sapflow

被引:171
作者
Phillips, N
Nagchaudhuri, A
Oren, R
Katul, G
机构
[1] Nicholas School of the Environment, Duke University, Durham
[2] School of Engineering, Turabo University, Gurabo
[3] Jet Propulsion Laboratory, California Institute of Technology, Pasadena
来源
TREES-STRUCTURE AND FUNCTION | 1997年 / 11卷 / 07期
关键词
tree transpiration; hydraulic resistance; hydraulic capacitance;
D O I
10.1007/s004680050102
中图分类号
S7 [林业];
学科分类号
0829 ; 0907 ;
摘要
The use of stem sap flow data to estimate diurnal whole-tree transpiration and canopy stomatal conductance depends critically upon knowledge of the time lag between transpiration and water flux through the stem. In this study, the time constant for water movement in stems of 12-year-old Pinus taeda L. individuals was estimated from analysis of time series data of stem water flux and canopy transpiration computed from mean daytime canopy conductance, and diurnal vapor pressure deficit and solar radiation measurements. Water uptake through stems was measured using a constant-heat sapflow probe. Canopy transpiration was correlated to stem uptake using a resistance-capacitance equation that incorporates a time constant parameter. A least-squares auto-regression determined the parameters of the resistance-capacitance equation. The time constants for ten loblolly pine trees averaged 48.0 (SE = 2.0) min and the time lag for the diurnal frequency averaged 47.0 (SE = 2.0) min. A direct-cross correlation analysis between canopy transpiration and sap flow time series showed maximum correlation at an approximately 30 min lag. Residuals (model-predicted minus actual stem flow data) increased with increasing soil moisture depletion. While the time constants did not vary significantly within the range of tree sizes studied, hydraulic resistance and capacitance terms were individually dependent on stem cross-sectional area: capacitance increased and resistance decreased with stem volume. This result may indicate an inverse adjustment of resistance and capacitance to maintain a similar time constant over the range of tree sizes studied.
引用
收藏
页码:412 / 419
页数:8
相关论文
共 34 条
[1]   COMPARISON OF 2 METHODS FOR ESTIMATING THE EVAPORATION OF A PINUS-PINASTER (AIT) STAND - SAP FLOW AND ENERGY-BALANCE WITH SENSIBLE HEAT-FLUX MEASUREMENTS BY AN EDDY COVARIANCE METHOD [J].
DIAWARA, A ;
LOUSTAU, D ;
BERBIGIER, P .
AGRICULTURAL AND FOREST METEOROLOGY, 1991, 54 (01) :49-66
[2]   ESTIMATING TRANSPIRATION FROM 6-YEAR-OLD EUCALYPTUS-GRANDIS TREES - DEVELOPMENT OF A CANOPY CONDUCTANCE MODEL AND COMPARISON WITH INDEPENDENT SAP FLUX MEASUREMENTS [J].
DYE, PJ ;
OLBRICH, BW .
PLANT CELL AND ENVIRONMENT, 1993, 16 (01) :45-53
[3]   A dynamic model for studying flow of water in single trees [J].
Edwards, W. R. N. ;
Jarvis, P. G. ;
Landsberg, J. J. ;
Talbot, H. .
TREE PHYSIOLOGY, 1986, 1 (03) :309-324
[4]   LEAF AND CANOPY RESPONSES TO ELEVATED CO2 IN A PINE FOREST UNDER FREE-AIR CO2 ENRICHMENT [J].
ELLSWORTH, DS ;
OREN, R ;
HUANG, C ;
PHILLIPS, N ;
HENDREY, GR .
OECOLOGIA, 1995, 104 (02) :139-146
[5]   MEASURING AND MODELING THE - TRANSPIRATION OF A MARITIME PINE CANOPY FROM SAP-FLOW DATA [J].
GRANIER, A ;
LOUSTAU, D .
AGRICULTURAL AND FOREST METEOROLOGY, 1994, 71 (1-2) :61-81
[6]   EVALUATION OF TRANSPIRATION IN A DOUGLAS-FIR STAND BY MEANS OF SAP FLOW MEASUREMENTS [J].
GRANIER, A .
TREE PHYSIOLOGY, 1987, 3 (04) :309-319
[7]  
GRESHAM C, 1975, THESIS DUKE U
[8]   COUPLING OF TREE TRANSPIRATION TO ATMOSPHERIC-TURBULENCE [J].
HOLLINGER, DY ;
KELLIHER, FM ;
SCHULZE, ED ;
KOSTNER, BMM .
NATURE, 1994, 371 (6492) :60-62
[9]   NON-STEADY-STATE WATER-FLOW FOR 3 DESERT PERENNIALS WITH DIFFERENT CAPACITANCES [J].
HUNT, ER ;
NOBEL, PS .
AUSTRALIAN JOURNAL OF PLANT PHYSIOLOGY, 1987, 14 (04) :363-375
[10]   EXTRAPOLATING PLANT WATER-FLOW RESISTANCES AND CAPACITANCES TO REGIONAL SCALES [J].
HUNT, ER ;
RUNNING, SW ;
FEDERER, CA .
AGRICULTURAL AND FOREST METEOROLOGY, 1991, 54 (2-4) :169-195