Radiologically guided percutaneous fine-needle aspiration biopsy of the liver: Retrospective study of 119 cases evaluating diagnostic effectiveness and clinical complications

被引:22
作者
Guo, ZW [1 ]
Kurtycz, DFI [1 ]
Salem, R [1 ]
De Las Casas, LE [1 ]
Caya, JG [1 ]
Hoerl, HD [1 ]
机构
[1] Univ Wisconsin, State Lab Hyg, Sch Med, Dept Pathol & Lab Med, Madison, WI 53706 USA
关键词
liver; neoplasms biopsy; fine-needle aspiration; complications; on-site assessment;
D O I
10.1002/dc.10097
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We reviewed 719 percutaneous, radiologically guided fine-needle aspirations (FNA) from 114 patients with liver masses to evaluate diagnostic effectiveness and complications of this procedure. Satisfactory material was obtained in 118 cases (99%), of which 78 were diagnosed as positive (66%), three suspicious (2%), five atypical (4%), and 32 (27%) as negative for malignancy. Compared to surgical biopsy (48 cases) and clinical data, the sensitivity and specificity of FNA for malignancy was 95.1% and 100%, respectively, yielding a positive predictive value of 100% and a negative predictive value of 88.8%. Four cytology cases (3.4%) were false-negatives (FN); all were interpretive errors. Four FN surgical biopsies (8.3%) were sampling errors. Minor complications occurred in three cases (2.5%). We conclude that FNA is safe and effective for determining the malignant potential of liver masses and should be the procedure of choice. Our experience suggests that having a pathologist present in the radiology suite provides optimal patient care. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 25 条
[1]  
BOTTLES K, 1988, CANCER, V62, P558, DOI 10.1002/1097-0142(19880801)62:3<558::AID-CNCR2820620320>3.0.CO
[2]  
2-2
[3]   CYTOLOGIC CRITERIA TO DISTINGUISH HEPATOCELLULAR-CARCINOMA FROM NONNEOPLASTIC LIVER [J].
COHEN, MB ;
HABER, MM ;
HOLLY, EA ;
AHN, DK ;
BOTTLES, K ;
STOLOFF, AC .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1991, 95 (02) :125-130
[4]  
Das DK, 1999, DIAGN CYTOPATHOL, V21, P370, DOI 10.1002/(SICI)1097-0339(199912)21:6<370::AID-DC2>3.0.CO
[5]  
2-K
[6]  
Dodd LG, 1997, RADIOLOGY, V203, P1
[7]  
DROESE M, 1984, ACTA CYTOL, V28, P368
[8]   IMAGING-GUIDED AND NONIMAGING-GUIDED FINE NEEDLE ASPIRATION OF LIVER-LESIONS - EXPERIENCE WITH 406 PATIENTS [J].
EDOUTE, Y ;
TIBONFISHER, O ;
BENHAIM, SA ;
MALBERGER, E .
JOURNAL OF SURGICAL ONCOLOGY, 1991, 48 (04) :246-251
[9]  
EDOUTE Y, 1992, AM J GASTROENTEROL, V87, P1138
[10]  
Hertz G, 2000, DIAGN CYTOPATHOL, V23, P326, DOI 10.1002/1097-0339(200011)23:5<326::AID-DC8>3.0.CO