Magnetic resonance cholangiopancreatography: Comparison between respiratory-triggered turbo spin echo and breath hold single-shot turbo spin echo sequences

被引:18
作者
Papanikolaou, N [1 ]
Karantanas, AH [1 ]
Heracleous, E [1 ]
Costa, JC [1 ]
Gourtsoyiannis, N [1 ]
机构
[1] Philips Greece Med Syst, Athens 15561, Greece
关键词
bile ducts; cholangiography; turbo spin echo; comparative study;
D O I
10.1016/S0730-725X(99)00074-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare the relative conspicuity of the pancreaticobiliary tree on respiratory-triggered three-dimensional turbo spin echo (3D TSE RT) and breath hold single-shot turbo spin echo (SSTSE BH) acquisitions respectively in MRCP imaging. Both techniques were applied to 61 patients with clinically suspected pancreaticobiliary disease using a 1.0 T MR system. All images were reviewed blindly, Qualitative comparison was made by grading subjectively the conspicuity of extrahepatic, intrahepatic, and main pancreatic ducts. Quantitative comparison included calculations of signal-to-noise ratio of the common bile duct, main pancreatic duct, gallbladder, liver, and contrast-to-noise ratio, relative contrast between common bile duct, gallbladder, and liver. 3D TSE RT provided significantly higher signal-to-noise ratio of the common bile duct (mean value 163.19) and main pancreatic duct (mean value 95.37) compared to SSTSE BH (mean values 76.24 and 26.22, respectively). 3D TSE RT was inferior to SSTSE BH for the depiction of intrahepatic ducts and pancreatic duct (head portion). 3D TSE RT and SSTSE BH sequences provide complimentary information in the visualization of the biliary and pancreatic ducts. Further comparative clinical studies are needed to redefine the sensitivity, specificity, and accuracy of MRCP using both sequences. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:1255 / 1260
页数:6
相关论文
共 17 条
[1]   MR-CHOLANGIOPANCREATOGRAPHY - EFFICACY OF 3-DIMENSIONAL TURBO SPIN-ECHO TECHNIQUE [J].
BARISH, MA ;
YUCEL, EK ;
SOTO, JA ;
CHUTTANI, R ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :295-300
[2]   Breath-hold MR cholangiopancreatography using a HASTE sequence: Comparison of single-slice and multislice acquisition techniques [J].
Ernst, O ;
Calvo, M ;
Sergent, G ;
Mizrahi, D ;
Carpentier, F .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) :1304-1306
[3]   DIAGNOSIS OF CHOLEDOCHOLITHIASIS - VALUE OF MR CHOLANGIOGRAPHY [J].
GUIBAUD, L ;
BRET, PM ;
REINHOLD, C ;
ATRI, M ;
BARKUN, ANG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (04) :847-850
[4]   BREATH-BOLD PROJECTION MAGNETIC-RESONANCE CHOLANGIO-PANCREATICOGRAPHY (MRCP) - A NEW METHOD FOR THE EXAMINATION OF THE BILE AND PANCREATIC DUCTS [J].
LAUBENBERGER, R ;
BUCHERT, M ;
SCHNEIDER, B ;
BLUM, U ;
HENNIG, J ;
LANGER, M .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) :18-23
[5]   Extrahepatic biliary diseases: 3D MR cholangiopancreatography compared with endoscopic retrograde cholangiopancreatography [J].
Lee, MG ;
Lee, HJ ;
Kim, MH ;
Kang, EM ;
Kim, YH ;
Lee, SG ;
Kim, PN ;
Ha, HK ;
Auh, YH .
RADIOLOGY, 1997, 202 (03) :663-669
[6]   MR cholangiopancreatography using HASTE (half-Fourier acquisition single-shot turbo spin-echo) sequences [J].
Miyazaki, T ;
Yamashita, Y ;
Tsuchigame, T ;
Yamamoto, H ;
Urata, J ;
Takahashi, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1297-1303
[7]   BILIARY OBSTRUCTION - EVALUATION WITH 3-DIMENSIONAL MR CHOLANGIOGRAPHY [J].
MORIMOTO, K ;
SHIMOI, M ;
SHIRAKAWA, T ;
AOKI, Y ;
CHOI, S ;
MIYATA, Y ;
HARA, K .
RADIOLOGY, 1992, 183 (02) :578-580
[8]   Choledocholithiasis: Evaluation with MR cholangiography [J].
Regan, F ;
Fradin, J ;
Khazan, R ;
Bohlman, M ;
Magnuson, T .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (06) :1441-1445
[9]   MR cholangiopancreatography [J].
Reinhold, C ;
Bret, PM .
ABDOMINAL IMAGING, 1996, 21 (02) :105-116
[10]   Imaging findings of pancreaticobiliary duct diseases with single-shot MR cholangiopancreatography [J].
Reuther, G ;
Kiefer, B ;
Tuchmann, A ;
Pesendorfer, FX .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (02) :453-459