Has the Quick or the Owren prothrombin time method the advantage in harmonization for the International Normalized Ratio system?

被引:12
作者
Horsti, J [1 ]
机构
[1] Tampere Univ Hosp, Dist Hosp Valkaekoski, Valkeakoski, Finland
关键词
prothrombin time; International Normalized Ratio; International Sensitivity Index;
D O I
10.1097/00001721-200210000-00010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prothrombin time (PT) is the most commonly used coagulation test in health care. We sought here to compare two major PT methods (Quick and Owren) for harmonization of International Normalized Ratio (INR) results. We measured PT with an ACL 7000 analyser. We used three Owren and three Quick reagents for PT, and estimated the International Sensitivity Index (ISI) for each reagent using two local and two manufactured ISI calibrator sets. The coagulation time was measured using five different normal plasmas to assess variation for every reagent and both methods. We studied the analytical bias for every reagent and both methods at INR = 1.0 and INR = 2.5. The mean percentage coefficient of variation of the Owren reagent ISI was 2.40% and that of the Quick reagent ISI was 12.85%. The mean percentage coefficient of variation of normal plasma seconds for the Owren method was 2.54% and that for Quick was 4.02%. The absolute error at INR = 1.0 and INR = 2.5 was 0.00 and 0.04 INR for Owren, and 0.01 and 0.16 INR for Quick. The Owren PT method has the advantage over the Quick PT method in ISI calibration, normal plasma variation, within-run analytical variation and absolute error at INR = 2.5. The INR system is more demanding on analytical quality than earlier units (Ratio,%). The data would indicate that the Owren PT method has advantages over the Quick PT method in harmonization of the INR system. (C) 2002 Lippincott Williams Wilkins.
引用
收藏
页码:641 / 646
页数:6
相关论文
共 30 条
  • [1] Adcock DM, 1997, AM J CLIN PATHOL, V107, P105
  • [2] Assessment of the influence of citrate concentration on the international normalized ratio (INR) determined with twelve reagent-instrument combinations
    Chantarangkul, V
    Tripodi, A
    Clerici, M
    Negri, B
    Mannucci, PM
    [J]. THROMBOSIS AND HAEMOSTASIS, 1998, 80 (02) : 258 - 262
  • [3] Local INR correction: justification for a simplified approach
    Craig, S
    Stevenson, KJ
    Duffy, JMK
    Taberner, DA
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1997, 50 (09) : 783 - 789
  • [4] THE RELIABILITY OF MANUFACTURER-DETERMINED, INSTRUMENT-SPECIFIC INTERNATIONAL SENSITIVITY INDEX VALUES FOR CALCULATING THE INTERNATIONAL NORMALIZED RATIO
    CUNNINGHAM, MT
    JOHNSON, GF
    PENNELL, BJ
    OLSON, JD
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1994, 102 (01) : 128 - 133
  • [5] DUNCAN EM, 1994, THROMB HAEMOSTASIS, V72, P84
  • [6] HERMANS J, 1983, THROMB HAEMOSTASIS, V50, P712
  • [7] Mechanism of action, clinical effectiveness, and optimal therapeutic range
    Hirsh, J
    Dalen, JE
    Anderson, DR
    Poller, L
    Bussey, H
    Ansell, J
    Deykin, D
    Brandt, JT
    [J]. CHEST, 1998, 114 (05) : 445S - 469S
  • [8] Comparison of Quick and Owren prothrombin time with regard to the harmonisation of the International Normalised Ratio (INR) system
    Horsti, J
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (04) : 399 - 403
  • [9] Horsti J, 2001, HAEMATOLOGICA, V86, P851
  • [10] Horsti J, 2001, CLIN CHEM, V47, P940