摘要
Background. This study assessed the effect of prolonged left ventricular unloading on native ventricular function. Methods. We reviewed data from 31 patients (30 men, 1 woman) supported more than 30 days (mean, 137 days; range, 31 to 505 days) with the HeartMate left ventricular assist system. The patients' mean age was 46 years (range, 22 to 64 years); 17 had idiopathic and 14 had ischemic cardiomyopathy. Data (anatomic, physiologic, hemodynamic, histologic, and biochemical) were collected at the time of HeartMate implantation, during support with the device temporarily oh, and at the time of device explantation. Results. Routine chest roentgenogram showed improvement in cardiothoracic ratio (0.62 +/- 0.04 to 0.55 +/- 0.03; p < 0.0001). Echocardiography performed with the pump off showed a significant decrease in left ventricular end-diastolic dimension (6.81 +/- 0.87 cm to 5.39 +/- 1.08 cm; p < 0.0005) and a significant improvement in ejection fraction (0.11 +/- 0.05 to 0.22 +/- 0.17; p < 0.02). Cardiac index increased (1.96 +/- 0.52 L . min(-1). m(-2) to 2.93 +/- 0.73 L . min(-1) m(-2); p < 0.0001), mean aortic pressure increased (71.40 +/- 10.63 mm Hg to 76.33 +/- 16.84 mm Hg; p = 0.48), pulmonary capillary wedge pressure decreased (24.18 +/- 6.27 mm Hg to 14.48 +/- 3.01 mm Hg; p < 0.0001), and pulmonary vascular resistance decreased (3.34 +/- 2.00 Wood units to 2.51 +/- 0.88 Wood units; p < 0.05). Comparisons of tissue samples taken at the time of implantation and at the time of transplantation showed a marked reduction in myocytolysis. Calcium uptake, calcium-binding rates, and lipid levels normalized in patients studied. Plasma norepinephrine levels decreased to near normal levels. Conclusion. Prospective studies are now indicated to determine whether device removal without transplantation may be beneficial in selected patients.
引用
收藏
页码:675 / 681
页数:7
相关论文
共 29 条
[1]  
BAUR LHB, 1991, BRIT HEART J, V65, P137
[3]   ON RESTING HUMAN HEART [J].
BURCH, GE ;
DEPASQUALE, NP .
AMERICAN HEART JOURNAL, 1966, 71 (03) :422-+
[4]  
Frazier O. H., 1994, Journal of Heart and Lung Transplantation, V13, pS51
[5]   FIRST USE OF AN UNTETHERED, VENTED ELECTRIC LEFT-VENTRICULAR ASSIST DEVICE FOR LONG-TERM SUPPORT [J].
FRAZIER, OH .
CIRCULATION, 1994, 89 (06) :2908-2914
[6]   IMPROVED MORTALITY AND REHABILITATION OF TRANSPLANT CANDIDATES TREATED WITH A LONG-TERM IMPLANTABLE LEFT-VENTRICULAR ASSIST SYSTEM [J].
FRAZIER, OH ;
ROSE, EA ;
MCCARTHY, P ;
BURTON, NA ;
TECTOR, A ;
LEVIN, H ;
KAYNE, HL ;
POIRIER, VL ;
DASSE, KA .
ANNALS OF SURGERY, 1995, 222 (03) :327-338
[7]  
FRAZIER OH, 1993, CARDIAC SURG STATE A, V7, P353
[8]  
HALL S, 1994, CIRCULATION, V90, P543
[9]  
Harasaki H, 1985, Trans Am Soc Artif Intern Organs, V31, P73
[10]  
HUSSAIN MN, 1985, CLIN CHEM, V31, P1861