Exposure chain of urban air PM2.5 -: associations between ambient fixed site, residential outdoor, indoor, workplace and personal exposures in four European cities in the EXPOLIS-study

被引:77
作者
Kousa, A
Oglesby, L
Koistinen, K
Künzli, N
Jantunen, M
机构
[1] KTL, Dept Environm Hyg, Natl Publ Hlth Inst, Kuopio, Finland
[2] Univ Basel, Inst Social & Prevent Med, Basel, Switzerland
[3] Inst Environm, EU Joint Res Ctr, Air Qual Unit, I-21020 Ispra, Italy
基金
美国国家科学基金会; 芬兰科学院;
关键词
exposure; correlation; EXPOLIS; regression model; PM2.5;
D O I
10.1016/S1352-2310(02)00232-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the EXPOLIS study personal exposures and microenvironment levels of air pollutants from 50-201 urban adult (25-55 yr) participants were measured in six European cities during 1 yr from autumn 1996 to winter 1997-98. This paper presents the associations between the personal PM2.5 exposures, microenvironment (residential indoor, residential outdoor and workplace indoor) and ambient fixed site concentrations measured in Helsinki (Finland), Basel (Switzerland), Prague (Czech Republic) and Athens (Greece). Considering the whole chain from ambient fixed site to residential outdoor, residential indoor and personal leisure time (non-working hours) exposure, the correlations were highest between personal leisure time exposures and residential indoor concentrations (non-environmental tobacco smoke (ETS): Pearson r = 0.72 - 0.92, ETS included: r = 0.82 - 0.86) except in Athens, where the correlation between residential indoor and outdoor air was highest (non-ETS: r = 0.82, ETS included: r = 0.68). Unfortunately, ambient fixed site PM2.5 concentrations were measured continuously only in Helsinki. Ambient fixed site PM2.5 concentrations correlated quite well with residential outdoor concentrations (r = 0.90), and also with residential indoor (non-ETS) concentrations (r = 0.80), but concentrations measured at ambient fixed site monitors were poor predictors of personal exposures to PM2.5. They were particularly poor predictors of personal workday exposures (non-ETS: r = 0.34, ETS included: r = 0.25), but considerably better for personal leisure time exposures (non-ETS: r = 0.69, ETS included: r = 0.54). According to log-linear regression models combined from all centres of non-ETS-exposed participants, residential indoor concentrations explained 76% of personal leisure time PM2.5 exposure variation and workplace indoor concentrations explained 66% of the workday exposure variation. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3031 / 3039
页数:9
相关论文
共 32 条
[1]   Spatial variation in particulate concentrations within metropolitan Philadelphia [J].
Burton, RM ;
Suh, HH ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (02) :400-407
[2]   Spatial variation of aerosol number concentration in Helsinki city [J].
Buzorius, G ;
Hämeri, K ;
Pekkanen, J ;
Kulmala, M .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (04) :553-565
[3]  
CLAYTON CA, 1993, J EXPO ANAL ENV EPID, V3, P227
[4]   AN ASSOCIATION BETWEEN AIR-POLLUTION AND MORTALITY IN 6 UNITED-STATES CITIES [J].
DOCKERY, DW ;
POPE, CA ;
XU, XP ;
SPENGLER, JD ;
WARE, JH ;
FAY, ME ;
FERRIS, BG ;
SPEIZER, FE .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (24) :1753-1759
[5]   ACUTE RESPIRATORY EFFECTS OF PARTICULATE AIR-POLLUTION [J].
DOCKERY, DW ;
POPE, CA .
ANNUAL REVIEW OF PUBLIC HEALTH, 1994, 15 :107-132
[6]  
Janssen NAH, 1998, AM J EPIDEMIOL, V147, P537
[7]  
Jantunen MJ, 1998, J EXPO ANAL ENV EPID, V8, P495
[8]  
JANTUNEN MJ, 1999, PUBLICATIONS NATL PU
[9]   Indoor/outdoor relationships of particulate matter in domestic homes with roadside, urban and rural locations [J].
Jones, NC ;
Thornton, CA ;
Mark, D ;
Harrison, RM .
ATMOSPHERIC ENVIRONMENT, 2000, 34 (16) :2603-2612
[10]   INDOOR OUTDOOR CONCENTRATIONS AND CORRELATIONS OF PM10-ASSOCIATED MUTAGENIC ACTIVITY IN NONSMOKERS AND ASTHMATICS HOMES [J].
KADO, NY ;
COLOME, SD ;
KLEINMAN, MT ;
HSIEH, DPH ;
JAQUES, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (06) :1073-1078