Characteristic behavior of macro-, semimicro- and microelectrodes in voltammetric and chronoamperometric measurements

被引:20
作者
Nirmaier, HP
Henze, G
机构
[1] UNIV TRIER,ANALYT CHEM LAB,D-54228 TRIER,GERMANY
[2] UNIV KAISERSLAUTERN,DEPT CHEM,D-67663 KAISERSLAUTERN,GERMANY
关键词
microelectrodes; chronoamperometry; resistive meolium; diffusion; RAM electrode; graphite epoxy electrode;
D O I
10.1002/elan.1140090808
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The advantages of microelectrodes such as the improvement of signal-to-noise ratio, the ability to perform electrochemical measurements in high resistive solutions and small RC-time constants give the possibility of an extended use for voltammetric and chronoamperometric techniques in analytical chemistry. In this comparative study, the microelectrode properties of three selected electrodes were examined. The characterization of a RAM-microarray electrode, an epoxy-impregnated carbon electrode and a conventional glassy carbon macroelectrode was performed by cyclic voltammetry at different scan rates, by DP-voltammetric measurements using different concentrations of supporting electrolyte and by transient measurements. It could be shown, that in comparison to the microarray electrode and to the glassy carbon macroelectrode, respectively, the results obtained by using the epoxy-impregnated carbon electrode are caused by its semimicroelectrode character.
引用
收藏
页码:619 / 624
页数:6
相关论文
共 17 条
[1]   ELECTROCHEMICAL DETECTION IN OPEN-TUBULAR COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY USING A PLATINUM MICROELECTRODE AND CO2 WATER AS MOBILE-PHASE [J].
ALMQUIST, SR ;
NYHOLM, L ;
MARKIDES, KE .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1994, 6 (05) :495-501
[2]   ELECTROCHEMISTRY IN ORGANIC-SOLVENTS WITHOUT SUPPORTING ELECTROLYTE USING PLATINUM MICROELECTRODES [J].
BOND, AM ;
FLEISCHMANN, M ;
ROBINSON, J .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 168 (1-2) :299-312
[3]   CHARACTERIZATION OF THICK-LAYER GRAPHITE DISPOSABLE VOLTAMMETRIC ELECTRODES [J].
BRAININA, KZ ;
BOND, AM .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2586-2591
[4]   PULSE VOLTAMMETRIC TECHNIQUES AT MICROELECTRODES IN PURE SOLVENTS [J].
CISZKOWSKA, M ;
STOJEK, Z ;
OSTERYOUNG, J .
ANALYTICAL CHEMISTRY, 1990, 62 (04) :349-353
[5]   DETERMINATION OF HEAVY-METALS IN REAL SAMPLES BY ANODIC-STRIPPING VOLTAMMETRY WITH MERCURY MICROELECTRODES .2. APPLICATION TO RAIN AND SEA WATERS [J].
DANIELE, S ;
BALDO, MA ;
UGO, P ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1989, 219 (01) :19-26
[6]   DETERMINATION OF HEAVY-METALS IN REAL SAMPLES BY ANODIC-STRIPPING VOLTAMMETRY WITH MERCURY MICROELECTRODES .1. APPLICATION TO WINE [J].
DANIELE, S ;
BALDO, MA ;
UGO, P ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1989, 219 (01) :9-18
[7]  
Fleischmann M., 1987, Ultramicroelectrodes
[8]  
Fletcher S., 1994, Chemistry in Australia, V61, P80
[9]  
FLETCHER S, 1995, RAM ELECT INTRO
[10]   ELECTROCHEMICAL TREATMENT OF PYROLYTIC CARBON-FIBER ELECTRODES [J].
GONON, FG ;
FOMBARLET, CM ;
BUDA, MJ ;
PUJOL, JF .
ANALYTICAL CHEMISTRY, 1981, 53 (09) :1386-1389