Normalizing fractional moving blood volume estimates with power Doppler US: Defining a stable intravascular point with the cumulative power distribution function

被引:87
作者
Rubin, JM [1 ]
Bude, RO [1 ]
Fowlkes, JB [1 ]
Spratt, RS [1 ]
Carson, PL [1 ]
Adler, RS [1 ]
机构
[1] DIASONICS, SANTA CLARA, CA USA
关键词
blood; flow dynamics; blood vessels; US; ultrasound; (US); power Doppler studies; technology;
D O I
10.1148/radiology.205.3.9393532
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To normalize the power Doppler ultrasound (US) signal to the expected signal from 100% blood in the calculation of a fractional moving blood volume estimate. MATERIALS AND METHODS: To locate the signal from flowing blood with a consistent backscatter coefficient, the authors estimated the knee of the cumulative Doppler power distribution function. They used a now-tube phantom to test the use of this knee to locate a radial position that would fall into a region of high sheer stress and minimal rouleaux formation. They also studied how well the method normalized fractional moving blood volume estimates of the right renal cortex in a volunteer when simulating different body habitus and in a group of six healthy volunteers to estimate variability. RESULTS: Over five flow velocities and over undersaturated to severely oversaturated receiver gains, the calculated now-tube area was a mean 89% +/- 7 (+/- standard deviation) of a standard. In humans, the technique normalized the fractional moving blood volume estimates over an 8-dB receiver gain variation; the mean +/- standard deviation of fractional moving blood volume estimates for the six volunteers was 37.6% +/- 3.6. CONCLUSION: Vascularity estimates with power Doppler US are feasible with a normalization scheme based on the cumulative Doppler power distribution function.
引用
收藏
页码:757 / 765
页数:9
相关论文
共 43 条
[1]   DOPPLER ULTRASOUND COLOR FLOW IMAGING IN THE STUDY OF BREAST-CANCER - PRELIMINARY FINDINGS [J].
ADLER, DD ;
CARSON, PL ;
RUBIN, JM ;
QUINNREID, D .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (06) :553-559
[2]   TRANS-VAGINAL COLOR FLOW IMAGING - A POSSIBLE NEW SCREENING TECHNIQUE FOR OVARIAN-CANCER [J].
BOURNE, T ;
CAMPBELL, S ;
STEER, C ;
WHITEHEAD, MI ;
COLLINS, WP .
BRITISH MEDICAL JOURNAL, 1989, 299 (6712) :1367-1370
[3]   PULSUS TARDUS - ITS CAUSE AND POTENTIAL LIMITATIONS IN DETECTION OF ARTERIAL-STENOSIS [J].
BUDE, RO ;
RUBIN, JM ;
PLATT, JF ;
FECHNER, KP ;
ADLER, RS .
RADIOLOGY, 1994, 190 (03) :779-784
[4]  
Burns PN, 1996, CLIN RADIOL, V51, P50
[5]   The 3D and 2D color flow display of breast masses [J].
Carson, PL ;
Moskalik, AP ;
Govil, A ;
Roubidoux, MA ;
Fowlkes, JB ;
Normolle, D ;
Adler, DD ;
Rubin, JM ;
Helvie, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06) :837-849
[6]  
CARSON PL, 1993, ULTRASON, P1023, DOI 10.1109/ULTSYM.1993.339634
[7]   BREAST DISEASES - COLOR DOPPLER US IN DIFFERENTIAL-DIAGNOSIS [J].
COSGROVE, DO ;
KEDAR, RP ;
BAMBER, JC ;
ALMURRANI, B ;
DAVEY, JBN ;
FISHER, C ;
MCKINNA, JA ;
SVENSSON, WE ;
TOHNO, E ;
VAGIOS, E ;
ALSANJARI, NA .
RADIOLOGY, 1993, 189 (01) :99-104
[8]   COLOR DOPPLER SIGNALS FROM BREAST-TUMORS - WORK IN PROGRESS [J].
COSGROVE, DO ;
BAMBER, JC ;
DAVEY, JB ;
MCKINNA, JA ;
SINNETT, HD .
RADIOLOGY, 1990, 176 (01) :175-180
[9]   COLOR DOPPLER ULTRASONOGRAPHY STUDIES OF BENIGN AND MALIGNANT BREAST-LESIONS [J].
DIXON, JM ;
WALSH, J ;
PATERSON, D ;
CHETTY, U .
BRITISH JOURNAL OF SURGERY, 1992, 79 (03) :259-260
[10]  
Feynman R. P., 1964, FEYNMAN LECT PHYSICS, VII, P41