Electromagnetic navigation diagnostic bronchoscopy - A prospective study

被引:319
作者
Gildea, Thomas R.
Mazzone, Peter J.
Karnak, Demet
Meziane, Moulay
Mehta, Atul C.
机构
[1] Cleveland Clin Fdn, Dept Pulm Allergy & Crit Care Med, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
[3] Ankara Univ, Sch Med, Dept Chest Dis, TR-06100 Ankara, Turkey
关键词
diagnostic bronchoscopy; electromagnetic navigation; mediastinal lymph node; solitary pulmonary nodule; transbronchial biopsy;
D O I
10.1164/rccm.200603-344OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Rationale: Electromagnetic navigation bronchoscopy using super Dimension/Bronchus System is a novel method to increase diagnostic yield of peripheral and mediastinal lung lesions. Objectives: A prospective, open label, single-center, pilot study was conducted to determine the ability of electromagnetic navigation bronchoscopy to sample peripheral lung lesions and mediastinal lymph nodes with standard bronchoscopic instruments and demonstrate safety. Methods: Electromagnetic navigation bronchoscopy was performed using the superDimension/Bronchus system consisting of electromagnetic board, position sensor encapsulated in the tip of a steerable probe, extended working channel, and real-time reconstruction of previously acquired multiplanar computed tomography images. The final distance of the steerable probe to lesion, expected error based on the actual and virtual markers, and procedure yield was gathered. Measurements: 60 subjects were enrolled between December 2004 and September 2005. Mean navigation times were 7 +/- 6 min and 2 2 min for peripheral lesions and lymph nodes, respectively. The steerable probe tip was navigated to the target lung area in all cases. The mean peripheral lesions and lymph nodes size was 22.8 +/- 12.6 mm and 28.1 +/- 12.8 mm. Yield was determined by results obtained during the bronchoscopy per patient. Results: The yield/procedure was 74% and 100% for peripheral lesions and lymph nodes, respectively. A diagnosis was obtained in 80.3% of bronchoscopic procedures. A definitive diagnosis of lung malignancy was made in 74.4% of subjects. Pneumothorax occurred in two subjects. Conclusion: Electromagnetic navigation bronchoscopy is a safe method for sampling peripheral and mediastinal lesions with high diagnostic yield independent of lesion size and location.
引用
收藏
页码:982 / 989
页数:8
相关论文
共 44 条
[1]   Transbronchial biopsy using endobronchial ultrasonography with a guide sheath and virtual bronchoscopic navigation [J].
Asahina, H ;
Yamazaki, K ;
Onodera, Y ;
Kikuchi, E ;
Shinagawa, N ;
Asano, F ;
Nishimura, M .
CHEST, 2005, 128 (03) :1761-1765
[2]   Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules [J].
Baaklini, WA ;
Reinoso, MA ;
Gorin, AB ;
Sharafkanch, A ;
Manian, P .
CHEST, 2000, 117 (04) :1049-1054
[3]   Bronchoscopic Biopsy of Peripheral Lung Lesions Under Electromagnetic Guidance [J].
Becker, Heinrich D. ;
Herth, Felix ;
Ernst, Armin ;
Schwarz, Yehuda .
JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2005, 12 (01) :9-13
[4]   Lung cancer: clinical presentation and specialist referral time [J].
Buccheri, G ;
Ferrigno, D .
EUROPEAN RESPIRATORY JOURNAL, 2004, 24 (06) :898-904
[5]   Combining bronchoscopy and positron emission tomography for the diagnosis of the small pulmonary nodule ≤3 cm [J].
Chhajed, PN ;
Bernasconi, M ;
Gambazzi, F ;
Bubendorf, L ;
Rasch, H ;
Kneifel, S ;
Tamm, M .
CHEST, 2005, 128 (05) :3558-3564
[6]   TRANS-BRONCHIAL BIOPSY WITHOUT FLUOROSCOPY - A 5 YEAR EXPERIENCE IN OUTPATIENTS [J].
DEFENOYL, O ;
CAPRON, F ;
LEBEAU, B ;
ROCHEMAURE, J .
THORAX, 1989, 44 (11) :956-959
[7]  
DIACON AH, 2005, RESPIRATION HERRLISH, V72, P129
[8]  
Freedman Matthew, 2004, Thorac Surg Clin, V14, P43, DOI 10.1016/S1547-4127(04)00036-2
[9]  
Funakoshi Yasunobu, 2003, Interact Cardiovasc Thorac Surg, V2, P517, DOI 10.1016/S1569-9293(03)00078-1
[10]   TRANS-BRONCHIAL NEEDLE ASPIRATION IN THE PRACTICE OF BRONCHOSCOPY [J].
GAY, PC ;
BRUTINEL, WM .
MAYO CLINIC PROCEEDINGS, 1989, 64 (02) :158-162