Design of a compact 1 MV AMS system for biomedical research

被引:29
作者
Hughey, BJ
Klinkowstein, RE
Shefer, RE
Skipper, PL
Tannenbaum, SR
Wishnok, JS
机构
[1] MIT,DIV TOXICOL,CAMBRIDGE,MA 02139
[2] MIT,DEPT CHEM,CAMBRIDGE,MA 02139
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
D O I
10.1016/S0168-583X(96)00420-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The widespread use of accelerator mass spectrometry in biomedical research will require the development of cost-effective, laboratory-sized AMS systems which can be used in conjunction with conventional gas and fluid phase separation techniques. This paper describes the design of a low energy AMS system for the detection of C-14 and H-3 in labeled biological samples. The system utilizes a compact 1 MV tandem accelerator which incorporates a foil stripper. The low energy analyzer, accelerating column, and high energy analyzer are designed for efficient transport and analysis of both carbon and hydrogen beams using the minimum number of optical elements. ?The resulting instrument is very compact: the entire AMS system including the injector, ion source and high energy analyzer is just under 3 m wide and is approximately 1.3 m high and 1 m deep. The relatively small size of this system will allow its installation in most biomedical laboratory facilities. The system is predicted to provide a statistical precision of better than 2% for the quantitation of attomole samples.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 17 条
[1]  
[Anonymous], 1977, ORNL5206
[2]  
BRONK CR, 1989, RADIOCARBON, V31, P298
[3]   Experimental investigation of the destruction of 1 MeV (CH2)-C-12 molecules in single and double stripping foils [J].
Hughey, BJ ;
Shefer, RE ;
Klinkowstein, RE ;
Zhao, XL ;
Kieser, WE ;
Litherland, AE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 123 (1-4) :186-192
[4]   NEW DEVELOPMENTS IN BEAM TRANSPORT THROUGH TANDEM ACCELERATORS [J].
LARSON, JD .
NUCLEAR INSTRUMENTS & METHODS, 1974, 122 (1-2) :53-63
[5]   A VERSATILE HIGH-INTENSITY NEGATIVE-ION SOURCE [J].
MIDDLETON, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3) :139-150
[6]   A CO2 NEGATIVE-ION SOURCE FOR C-14 DATING [J].
MIDDLETON, R ;
KLEIN, J ;
FINK, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 43 (02) :231-239
[7]   A FUTURE AMS CHROMATOGRAPHY INSTRUMENT FOR BIOCHEMICAL AND ENVIRONMENTAL MEASUREMENTS [J].
PURSER, KH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 92 (1-4) :201-206
[8]   THE ELIMINATION OF CHARGE-CHANGING BACKGROUNDS IN AN AMS RADIOCARBON SYSTEM [J].
PURSER, KH ;
LITHERLAND, AE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 52 (3-4) :424-427
[9]  
PURSER KH, 1992, Patent No. 5120956
[10]   CARBON-DIOXIDE SPUTTER SOURCE DEVELOPMENT AT OXFORD [J].
RAMSEY, CB ;
HEDGES, REM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 92 (1-4) :100-104