Multiplex measurement of seven tumor markers using an electrochemical protein chip

被引:223
作者
Wilson, Michael S. [1 ]
Nie, Weiyan [1 ]
机构
[1] EIC Labs Inc, Norwood, MA 02062 USA
关键词
D O I
10.1021/ac060843u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical immunosensor for performing multi-analyte measurements of tumor markers is described. The sensor consisted of an array of immunosensing electrodes fabricated on a glass substrate. Each electrode contained a different immobilized antigen and was capable of measuring a specific tumor marker using electrochemical enzyme-based competitive immunoassay. Using this arrangement, multiple analytes could be measured simultaneously by performing the technical operations for a single assay. The biosensor was used to measure the concentrations of seven important tumor markers: AFP, ferritin, CEA, hCG-beta, CA 15-3, CA 125, and CA 19-9. The sensor had excellent precision and accuracy and was comparable in performance to single-analyte ELISAs (1.9-8.1% interassay CV; < 2 ng/mL ( or units/mL) detection limit for most analytes). Multianalyte assays provide significant advantages over single-analyte tests in terms of cost per test, labor, test throughput, and convenience. We anticipate that chip-based sensors, as described herein, will be suitable for the mass production of economical, miniaturized lab-on-a-chip devices that will have applications in a wide range of clinical, environmental, and biodefense applications.
引用
收藏
页码:6476 / 6483
页数:8
相关论文
共 38 条
[1]   Microfluidic immunosensor systems [J].
Bange, A ;
Halsall, HB ;
Heineman, WR .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2488-2503
[2]  
BEASON KL, 2002, J MISS ACAD SCI, V47, P175
[3]  
Carpelan-Holmström M, 2002, ANTICANCER RES, V22, P2311
[4]   Immunoassays based on electrochemical detection using microelectrode arrays [J].
Dill, K ;
Montgomery, DD ;
Ghindilis, AL ;
Schwarzkopf, KR ;
Ragsdale, SR ;
Oleinikov, AV .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (04) :736-742
[5]   Immunological assay for carbohydrate antigen 19-9 using an electrochemical immunosensor and antigen immobilization in titania sol-gel matrix [J].
Du, D ;
Yan, F ;
Liu, SL ;
Ju, HX .
JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 283 (1-2) :67-75
[6]   α-fetoprotein and β-human chorionic gonadotropin -: Their clinical significance as tumour markers [J].
Gregory, JJ ;
Finlay, JL .
DRUGS, 1999, 57 (04) :463-467
[7]   Methods and applications of antibody microarrays in cancer research [J].
Haab, BB .
PROTEOMICS, 2003, 3 (11) :2116-2122
[8]   A prospective multicenter trial evaluating diagnostic validity of multivariate analysis and individual serum marker in differential diagnosis of pancreatic cancer from benign pancreatic diseases [J].
Hayakawa, T ;
Naruse, S ;
Kitagawa, M ;
Ishiguro, H ;
Kondo, T ;
Kurimoto, K ;
Fukushima, M ;
Takayama, T ;
Horiguchi, Y ;
Kuno, N ;
Noda, A ;
Furukawa, T .
INTERNATIONAL JOURNAL OF PANCREATOLOGY, 1999, 25 (01) :23-29
[9]   SIMULTANEOUS IMMUNOASSAY USING ELECTROCHEMICAL DETECTION OF METAL-ION LABELS [J].
HAYES, FJ ;
HALSALL, HB ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1860-1865
[10]   A polymer-based microfluidic device for immunosensing biochips [J].
Ko, JS ;
Yoon, HC ;
Yang, HS ;
Pyo, HB ;
Chung, KH ;
Kim, SJ ;
Kim, YT .
LAB ON A CHIP, 2003, 3 (02) :106-113