Plasmodium falciparum histidine-rich protein 2-based immunocapture diagnostic assay for malaria:: Cross-reactivity with rheumatoid factors

被引:71
作者
Iqbal, J
Sher, A
Rab, A
机构
[1] Kuwait Univ, Fac Med, Dept Microbiol, Safat 13110, Kuwait
[2] Healthnet, Peshawar, Pakistan
[3] Minist Hlth, Malaria Lab, Kuwait, Kuwait
关键词
D O I
10.1128/JCM.38.3.1184-1186.2000
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Recently introduced rapid nonmicroscopic immunocapture assays for the diagnosis of malaria infection are being evaluated for their sensitivity and specificity in various epidemiological settings. A Plasmodium falciparum histidine-rich protein 2 (PfHRP-2)-based assay (ICT) and a Plasmodium-specific lactate dehydrogenase test (OptiMAL) were evaluated for their specificities in different groups of patients who tested negative for malaria infection by microscopy. The patients were selected from different disease groups: rheumatoid arthritis, hepatitis C, toxoplasmosis, schistosomiasis, and hydatid disease. One hundred thirty-three of the 225 patients were positive for rheumatoid factor. Thirty-five of the 133 (26%) rheumatoid factor-positive patients gave a false-positive reaction with the ICT assay, but only 4 of these gave false-positive reactions with the OptiMAL test. Thirty-three of the 35 false-positive specimens became negative when repeat tested with the ICT assay after absorbing out the rheumatoid factor activity. Our study shows that the PfHRP-2-based ICT assay gave a false-positive reaction in 26% of the patients who had rheumatoid factors, but were negative for malaria by microscopy.
引用
收藏
页码:1184 / 1186
页数:3
相关论文
共 16 条
[1]  
ADEBAJO AO, 1994, J RHEUMATOL, V21, P968
[2]   False positive ParaSight™-F test for malaria in patients with rheumatoid factor [J].
Bartoloni, A ;
Strohmeyer, M ;
Sabatinelli, G ;
Benucci, M ;
Serni, U ;
Paradisi, F .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1998, 92 (01) :33-34
[3]   Performance of two rapid tests for Plasmodium falciparum malaria in patients with rheumatoid factors [J].
Bartoloni, A ;
Sabatinelli, G ;
Benucci, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (15) :1075-1075
[4]   DIAGNOSIS OF MALARIA BY DETECTION OF PLASMODIUM-FALCIPARUM HRP-2 ANTIGEN WITH A RAPID DIPSTICK ANTIGEN-CAPTURE ASSAY [J].
BEADLE, C ;
LONG, GW ;
WEISS, WR ;
MCELROY, PD ;
MARET, SM ;
OLOO, AJ ;
HOFFMAN, SL .
LANCET, 1994, 343 (8897) :564-568
[5]   Comparison of a parasite lactate dehydrogenase-based immunochromatographic antigen detection assay (Optimal®) with microscopy for the detection of malaria parasites in human blood samples [J].
Cooke, AH ;
Chiodini, PL ;
Doherty, T ;
Moody, AH ;
Ries, J ;
Pinder, M .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1999, 60 (02) :173-176
[6]   Immunochromatographic test for malaria diagnosis [J].
Garcia, M ;
Kirimoama, S ;
Marlborough, D ;
Leafasia, J ;
Riechmann, KH .
LANCET, 1996, 347 (9014) :1549-1549
[7]   ParaSight(R)F test compared with the polymerase chain reaction and microscopy for the diagnosis of Plasmodium falciparum malaria in travelers [J].
Humar, A ;
Ohrt, C ;
Harrington, MA ;
Pillai, D ;
Kain, KC .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1997, 56 (01) :44-48
[8]   PLASMODIUM-FALCIPARUM - ANALYSIS OF THE CYTOADHERENCE INHIBITION OF THE HUMAN MONOCLONAL ANTIBODY-33G2 AND OF ANTIBODIES REACTIVE WITH ANTIGEN PF332 [J].
IQBAL, J ;
PERLMANN, P ;
BERZINS, K .
EXPERIMENTAL PARASITOLOGY, 1993, 77 (01) :79-87
[9]   False positive dipstick test for malaria [J].
Laferi, H ;
Kandel, K ;
Pichler, H .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 337 (22) :1635-1636
[10]  
LIPSKY PE, 1994, HARRISONS PRINCIPLES, P1648