A flow cytometric technique for quantification and differentiation of bacteria in bulk tank milk

被引:38
作者
Holm, C
Mathiasen, T
Jespersen, L
机构
[1] Royal Vet & Agr Univ KVL, Dept Dairy & Food Sci Food Microbiol, DK-1958 Frederiksberg C, Denmark
[2] DAnish Dairy Board, Dept Vet & Milk Qual, Aarhus C, Denmark
[3] FOSS Analyt AS, Hillerod, Denmark
关键词
bacteria; flow cytometry; fluorescence; hygiene; mastitis; milk; psychrotrophic;
D O I
10.1111/j.1365-2672.2004.02346.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Aims: The present study describes a flow cytometric technique for quantification and differentiation of bacteria in bulk tank milk according to the main cause of elevated counts. Methods and Results: A total of 75 Danish bulk tank milk samples exceeding the grading level of 3.0 x 10(4) CFU ml(-1) were examined by both flow cytometry and traditional microbiological analyses. The correlation coefficient (r) between the two methods was 0.71. For the differential analyses of the dominant bacterial populations four different parameters were used to give a species-characteristic pattern. The four parameters were as follows: staining with Oregon Green((R)) conjugated wheat germ agglutinin that binds to the cell wall of bacteria, staining with hexidium iodide that binds to all bacterial DNA, the flow cytometric forward scatter and the flow cytometric side scatter. Three regions in the flow cytometric plot were defined: region 1 includes bacteria mainly associated with poor hygiene, region 2 includes psychrotrophic hygiene bacteria and region 3 includes bacteria mainly related to mastitis. The ability of the flow cytometric technique to predict the main cause of elevated bacterial counts on routine samples was examined. Comparing these results with results obtained by traditional microbiological analyses for identification showed that for 81% of the samples the two techniques agreed on the main cause of an elevated bacterial count. Conclusions: The ability of the presented flow cytometric technique to enumerate and differentiate bacteria in bulk tank milk according to the main cause of elevated counts was demonstrated. Significance and Impact of the Study: This study described the first step in development of a technique suitable for routine analyses of bulk tank milk samples. A technique indicating the main cause of an elevated count will enable the farmer to eliminate the contamination source within a short time limit.
引用
收藏
页码:935 / 941
页数:7
相关论文
共 26 条
[1]  
[Anonymous], 1991, 100B IDF
[2]  
[Anonymous], 1996, 122C IDF
[3]   Quality of pasteurized milk influences the performance of ready-to-use systems for enumeration of aerobic microorganisms [J].
Beloti, V ;
Barros, MD ;
Nero, LA ;
Pachemshy, JAD ;
de Santana, EHW ;
Franco, BDGM .
INTERNATIONAL DAIRY JOURNAL, 2002, 12 (05) :413-418
[4]  
Blowey R, 1997, IN PRACTICE, V19, P122
[5]  
Blowey R, 1999, IN PRACTICE, V21, P531
[6]  
Bolzoni G, 2000, MILCHWISSENSCHAFT, V55, P67
[7]  
Davey HM, 1999, CYTOMETRY, V35, P162, DOI 10.1002/(SICI)1097-0320(19990201)35:2<162::AID-CYTO8>3.0.CO
[8]  
2-U
[9]   METHOD FOR FLOW CYTOMETRIC DETECTION OF LISTERIA-MONOCYTOGENES IN MILK [J].
DONNELLY, CW ;
BAIGENT, GJ .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1986, 52 (04) :689-695
[10]   Optical instrument for the rapid detection of microorganisms in dairy products [J].
Firstenberg-Eden, R ;
Foti, DL ;
McDougal, ST ;
Baker, J .
INTERNATIONAL DAIRY JOURNAL, 2002, 12 (2-3) :225-232