A simplified method for HPLC determination of creatinine in mouse serum

被引:117
作者
Yuen, PST
Dunn, SR
Miyaji, T
Yasuda, H
Sharma, K
Star, RA
机构
[1] NIDDKD, NIH, Renal Diagnost & Therapeut Unit, Bethesda, MD 20892 USA
[2] Thomas Jefferson Univ, Dept Med, Div Nephrol, Dorrance Hamilton Res Labs, Philadelphia, PA 19107 USA
关键词
Jaffe assay; mouse models; renal failure;
D O I
10.1152/ajprenal.00366.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Mouse models are frequently used to study renal function. However, mouse serum contains chromagens that interfere with standard picric acid-based assays for serum creatinine. Several alternative methods exist for serum creatinine measurements, including assay by high-performance liquid chromatography ( HPLC), but only one has been adapted to mouse serum. Creatinine was measured in serum by acetonitrile deproteinization, followed by isocratic, cation exchange HPLC. The HPLC method was compared with a standard alkaline picrate colorimetric assay, using serum from animals with low-to-moderate renal injury. Acidification of acetonitrile with HCl in the deproteinization step produced variable results, including an extra peak that interfered with integration of the creatinine peak or loss of the creatinine peak. Deproteinizing with acetonitrile alone resulted in a more reliable measurement of serum creatinine, which was validated by a series of known additions of creatinine standard. The HPLC assay was reproducible with coefficients of variation from 1.6 to 5.1%. The picric acid assay overestimated serum creatinine, when directly compared with the HPLC assay. The extent of overestimation, up to sixfold, was greatest at normal (0.1 to 0.2 mg/dl) to moderately elevated (0.5 mg/dl) serum creatinine levels. Mouse serum contains substances that interfere with standard picric acid assays for creatinine. Our new HPLC assay can accurately detect creatinine from 5 mul of mouse serum. These results support the widespread adoption of HPLC to accurately measure serum creatinine in mouse models of renal injury.
引用
收藏
页码:F1116 / F1119
页数:4
相关论文
共 7 条
[1]  
DUNN SR, IN PRESS KIDNEY INT
[2]   CHROMATOGRAPHY AND ELECTROPHORESIS OF CREATININE AND OTHER GUANIDINO COMPOUNDS [J].
HUANG, SM ;
HUANG, YC .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 429 :235-253
[3]  
Jaffe M., 1886, PHYSIOL CHEM PHYS M, V10, P391, DOI DOI 10.1515/BCHM1.1886.10.5.391
[4]   Simple high-performance liquid chromatographic method to analyze serum creatinine has several advantages over the Jaffe picric acid reaction as demonstrated with a cimetidine dose response in rhesus monkeys [J].
Johns, BA ;
Broten, T ;
Stranieri, MT ;
Holahan, MA ;
Cook, JJ .
JOURNAL OF CHROMATOGRAPHY B, 2001, 759 (02) :343-348
[5]  
Kasiske BL, 1996, BRENNER RECTORS KIDN, P1137
[6]   PICRIC ACID METHODS GREATLY OVERESTIMATE SERUM CREATININE IN MICE - MORE ACCURATE RESULTS WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
MEYER, MH ;
MEYER, RA ;
GRAY, RW ;
IRWIN, RL .
ANALYTICAL BIOCHEMISTRY, 1985, 144 (01) :285-290
[7]   Ethyl pyruvate decreases sepsis-induced acute renal failure and multiple organ damage in aged mice [J].
Miyaji, T ;
Hu, XZ ;
Yuen, PST ;
Muramatsu, Y ;
Iyer, S ;
Hewitt, SM ;
Star, RA .
KIDNEY INTERNATIONAL, 2003, 64 (05) :1620-1631