A silastic positioner for a modiolus-hugging position of intracochlear electrodes: Electrophysiologic effects

被引:40
作者
Cords, SM
Reuter, G
Issing, PR
Sommer, A
Kuzma, J
Lenarz, T
机构
[1] Med Hsch Hannover, Dept Otorhinolaryngol, Hannover, Germany
[2] Adv Bion Corp, Sylmar, CA USA
关键词
cats; cochlear implant; EABR; electrode position; spatial resolution; input-output function;
D O I
10.1016/S0196-0709(00)80011-3
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Hypothesis: It was postulated that an electrode array that achieved a close modiolar proximity would result in reduced threshold levels and amplitude slopes, as measured with electrically evoked auditory brainstem responses (EABRs). Background: Quality and quantity of auditory information transmitted by a cochlear implant to patients with sensorineural hearing loss depend on spatial and temporal resolution achieved by the electrical intracochlear stimulation. Methods: To improve spatial resolution, a new electrode system was developed by Advanced Bionics Corp., with the intention of obtaining greater modiolar proximity. The implant version specified for animal experiments consists of a straight electrode array of seven embedded platinum discs and a so-called Silastic-positioner. The Silastic positioner is shaped to Follow the dimensions of the scala tympani with a concave (triangular) inner side, which fits the form of the electrode array. The aim of the study was to evaluate the influence of a modiolus-hugging electrode position in contrast to a conventional electrode position on EABR in short-term animal experiments. Short-term electrophysiologic studies were performed on six adult cats. After local intracochlear application of neomycin solution (50 mg/mL), electrodes were inserted into the scala tympani. Electrically evoked auditory brainstem response threshold levels and EABR amplitude slopes were systematically investigated with and without the positioner. Results: Electrically evoked auditory brainstem response measurements revealed a distinct apicobasal threshold shift, with increasing thresholds toward the basal end of the electrode. After insertion of the positioner, this shift diminished or was inverted and EABR thresholds and amplitude slopes were reduced significantly. Conclusions: Threshold and amplitude slops data emphasize the functional benefit of the positioner system, especially for the stimulation of electrodes in the more basal channels.
引用
收藏
页码:212 / 217
页数:6
相关论文
共 20 条
[1]   ELECTRICALLY EVOKED BRAIN-STEM POTENTIALS IN COCHLEAR IMPLANT PATIENTS WITH MULTI-ELECTRODE STIMULATION [J].
ABBAS, PJ ;
BROWN, CJ .
HEARING RESEARCH, 1988, 36 (2-3) :153-162
[2]   ELECTRICALLY EVOKED AUDITORY BRAIN-STEM RESPONSE - GROWTH OF RESPONSE WITH CURRENT LEVEL [J].
ABBAS, PJ ;
BROWN, CJ .
HEARING RESEARCH, 1991, 51 (01) :123-138
[3]  
Black R C, 1983, Acta Otolaryngol Suppl, V399, P5
[4]   CURRENT DISTRIBUTIONS IN COCHLEAR STIMULATION [J].
BLACK, RC ;
CLARK, GM ;
TONG, YC ;
PATRICK, JF .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1983, 405 (JUN) :137-145
[5]   INDICATION OF A RELATION BETWEEN SPEECH-PERCEPTION AND TEMPORAL RESOLUTION FOR COCHLEAR IMPLANTEES [J].
CAZALS, Y ;
KASPER, A ;
PELIZZONE, M ;
MONTANDON, P .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1991, 100 (11) :893-895
[6]   POTENTIAL DISTRIBUTIONS AND NEURAL EXCITATION PATTERNS IN A ROTATIONALLY SYMMETRICAL MODEL OF THE ELECTRICALLY STIMULATED COCHLEA [J].
FRIJNS, JHM ;
DESNOO, SL ;
SCHOONHOVEN, R .
HEARING RESEARCH, 1995, 87 (1-2) :170-186
[7]   DIMENSIONS OF THE SCALA TYMPANI IN THE HUMAN AND CAT WITH REFERENCE TO COCHLEAR IMPLANTS [J].
HATSUSHIKA, S ;
SHEPHERD, RK ;
TONG, YC ;
CLARK, GM ;
FUNASAKA, S .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1990, 99 (11) :871-876
[8]   Spatial resolution of cochlear implants: the electrical field and excitation of auditory afferents [J].
Kral, A ;
Hartmann, R ;
Mortazavi, D ;
Klinke, R .
HEARING RESEARCH, 1998, 121 (1-2) :11-28
[9]  
KUZMA JA, 1998, P 7 S COCHL IMPL CHI, P22
[10]  
LENARZ T, 1998, P 4 EUR S PAED COCHL, P7