Assessment of left ventricular mass in mice: Comparison between two-dimensional and M-mode echocardiography

被引:28
作者
Kiatchoosakun, S [1 ]
Restivo, J [1 ]
Kirkpatrick, D [1 ]
Hoit, BD [1 ]
机构
[1] Univ Hosp Cleveland, Dept Med, Cleveland, OH 44106 USA
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2002年 / 19卷 / 03期
关键词
hypertrophy; ultrasound; remodeling; cardiomyopathy; heart failure;
D O I
10.1046/j.1540-8175.2002.00199.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: M-mode echocardiography has been used extensively for estimating left ventricular (LV) mass in mice, but accuracy is limited by its unidimensional nature. This study tested whether two-dimensional (2-D) echocardiographic measurement of LV mass using area-length and truncated ellipsoid methods overcomes this limitation. Methods: Twenty-five anesthetized FVB/N mice (Mus musculus) underwent high resolution (15 MHZ) two-dimensionally directed M-mode and 2-D echocardiography. End-diastolic epicardial and endocardial areas from short-axis views and the LV orthogonal long-axis views were measured, while LV mass was calculated by 2-D area-length and truncated ellipsoid methods. LV mass was calculated from M-mode using the uncorrected cube equation. Hearts were removed and weighed after completing the echocardiographic studies. The correlation and agreement between echocardiographic-determined LV mass and gravimetric LV weight were examined. Results: LV mass using the area-length method correlated better with autopsy LV weight (r = 0.87, slope = 0.87, standard error of the estimate [SEE] = 12.4 mg, P < 0.001) than M-mode echocardiography (r = 0.85, slope 0.71, SEE = 11.1 mg, P < 0.001), and the degree of agreement (bias +/- 2 SD) was better (10.2 +/- 25.1 mg vs 13.1 +/- 25.8 mg, P = NS). Although 2-D truncated ellipsoid LV mass showed a good correlation with necropsy LV weight (r = 0.87, slope = 0.78, SEE = 11.0 mg, P < 0.001), the agreement between the truncated ellipsoid estimates and LV weight was less than that between M-mode and gravimetric LV mass. Conclusions: The 2-D area-length method is an accurate method of LV mass determination in symmetrical ventricles and can be used as an alternative for in vivo measurement of LV mass in mice.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 18 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Noninvasive assessment and necropsy validation of changes in left ventricular mass in ascending aortic banded mice [J].
Fard, A ;
Wang, CY ;
Takuma, S ;
Skopicki, HA ;
Pinsky, DJ ;
Di Tullio, MR ;
Homma, S .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (06) :582-587
[3]   ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR MASS AND SYSTOLIC FUNCTION IN MICE [J].
GARDIN, JM ;
SIRI, FM ;
KITSIS, RN ;
EDWARDS, JG ;
LEINWAND, LA .
CIRCULATION RESEARCH, 1995, 76 (05) :907-914
[4]   Cardiac hypertrophy is not a required compensatory response to short-term pressure overload [J].
Hill, JA ;
Karimi, M ;
Kutschke, W ;
Davisson, RL ;
Zimmerman, K ;
Wang, ZY ;
Kerber, RE ;
Weiss, RM .
CIRCULATION, 2000, 101 (24) :2863-2869
[5]   In vivo echocardiographic assessment of left ventricular function in - Transgenic and gene-targeted mice [J].
Hoit, BD ;
Walsh, RA .
TRENDS IN CARDIOVASCULAR MEDICINE, 1997, 7 (04) :129-134
[6]   IN-VIVO ECHOCARDIOGRAPHIC DETECTION OF ENHANCED LEFT-VENTRICULAR FUNCTION IN GENE-TARGETED MICE WITH PHOSPHOLAMBAN DEFICIENCY [J].
HOIT, BD ;
HOURY, SF ;
KRANIAS, EG ;
BALL, N ;
WALSH, RA .
CIRCULATION RESEARCH, 1995, 77 (03) :632-637
[7]  
Lorell BH, 2000, CIRCULATION, V102, P470
[8]   IN-VIVO ASSESSMENT OF LV MASS IN MICE USING HIGH-FREQUENCY CARDIAC ULTRASOUND - NECROPSY VALIDATION [J].
MANNING, WJ ;
WEI, JY ;
KATZ, SE ;
LITWIN, SE ;
DOUGLAS, PS .
AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (04) :H1672-H1675
[9]  
Park S H, 1996, J Am Soc Echocardiogr, V9, P119, DOI 10.1016/S0894-7317(96)90019-X
[10]  
Pollick C, 1995, J Am Soc Echocardiogr, V8, P602, DOI 10.1016/S0894-7317(05)80373-6