Clinical performance of steroid-eluting pacing leads with 1.2-mm(2) electrodes

被引:16
作者
Danilovic, D [1 ]
Breivik, K [1 ]
Hoff, PI [1 ]
Ohm, OJ [1 ]
机构
[1] HAUKELAND UNIV HOSP,DEPT MED A,N-5021 BERGEN,NORWAY
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1997年 / 20卷 / 11期
关键词
electrode surface; electrode stability; high impedance; low threshold; high slew rates;
D O I
10.1111/j.1540-8159.1997.tb05438.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
DANILOVIC, D., ET AL.: Clinical Performance of Steroid-Eluting Pacing Leads with 1.2-mm(2) Electrodes. To raise pacing impedance and reduce battery current drain, new tined steroid-eluting leads were developed with 1.2-mm(2) hemispherical electrodes, instead of conventional 5-8 mm(2). Twenty-two unipolar J-shaped atrial leads and 25 unipolar ventricular leads (models 4533 and 4033, respectively) were implanted in 33 consecutive patients and followed for a mean of 25 months (range 18-29). Handling characteristics of atrial leads were found favorable. The leads slipped easily into the right atrial appendage and were easy to position. Handling characteristics of ventricular leads were satisfying, but more efforts had to be applied to cross the tricuspid valve. Special care was taken to avoid perforation of the myocardium due to the small lead tip. Following implantation, four ventricular and one atrial lead exhibited instability of pacing thresholds that resolved spontaneously within 1-3 days of implantation. Except for this, no lead malfunctioned. The reoperation rate was zero. The mean electrogram amplitudes of 25 mV (ventricle) and 4 mV (atrium), and the mean chronic pacing threshold of 0.085 ms at 1.6 V (app. 0.43 V at 0.5 ms) were comparable with the best values seen in the literature on passive fixation leads. The rest of the electrophysiological parameters were enhanced: mean pacing impedances were 984 Omega (acute) and 900 Omega (chronic), mean slew rates 3.26 V/s (ventricle) and 1.75 V/s (atrium), mean acute voltage threshold at 0.5 ms was 0.25 V mean current and energy thresholds calculated at 0.5 ms were 260 mu A and 32 nJ (acute) and 478 mu A and 103 nJ (chronic). The electrical characteristics of these leads provide for increased pacemaker longevity in combination with substantial safety margins for pacing and sensing.
引用
收藏
页码:2799 / 2809
页数:11
相关论文
共 41 条
[1]   OPTIMAL PACEMAKER SENSING WITH RESPECT TO AMPLITUDE AND SLEW RATE OF INTRACARDIAC ELECTROGRAMS - THEORETICAL-ANALYSIS BY COMPUTER-SIMULATION [J].
ARAI, Y ;
YAMAZOE, M ;
TOEDA, T ;
HOSHINO, Y ;
SHIBATA, A ;
MAKINO, H ;
SAITOH, Y .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (05) :778-783
[2]  
BERSOHN MM, 1994, PACE, V17, P854
[3]   ATRIAL AND VENTRICULAR STIMULATION THRESHOLD DEVELOPMENT - A COMPARATIVE-STUDY IN PATIENTS WITH A DDD PACEMAKER AND 2 IDENTICAL CARBON-TIP LEADS [J].
BRANDT, J ;
ATTEWELL, R ;
FAHRAEUS, T ;
SCHULLER, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (07) :859-866
[4]  
DANILOVIC D, 1995, REBLAMPA, V8, p22N7
[5]  
DANILOVIC D, 1996, EUR JCPE S5, V6, P221
[6]  
DANILOVIC D, 1996, EUR JCPE S5, V6, P217
[7]  
DANILOVIC D, 1996, EUR JCPE S5, V6, P169
[8]  
DANILOVIC D, 1995, PACE, V18, P1187
[9]  
ESCHER DJW, 1973, P 4 INT S CARD PAC A, P239
[10]   Initial experience with 1.5-mm(2) high impedance, steroid-eluting pacing electrodes [J].
Fogel, R ;
Pirzada, F ;
Casavant, D ;
Boone, J ;
Bowman, A ;
Steinhaus, D ;
Gilbert, M ;
Vlietstra, R ;
Belott, P ;
Parsonnet, V ;
Tilton, G ;
White, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (02) :188-196