Characterization of indoor particle sources: A study conducted in the metropolitan Boston area

被引:280
作者
Abt, E
Suh, HH
Allen, G
Koutrakis, P
机构
[1] CNR, Board Environm Studies & Toxicol, Washington, DC 20418 USA
[2] Harvard Univ, Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
关键词
air exchange rate; ambient concentrations; indoor particle sources; particle size distributions; particle decay;
D O I
10.2307/3454293
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pm intensive particle monitoring study was conducted in homes in the Boston, Massachusetts, area during the winter and summer of 1996 in an effort to characterize sources of indoor particles. As part of this study, continuous particle size and mass concentration data were collected in four single-family homes, with each home monitored for one or two 6-day periods. Additionally, housing activity and air exchange rate data were collected. Cooking, cleaning, and the movement of people were identified as the most important indoor particle sources in these homes. These sources contributed significantly both to indoor concentrations (indoor-outdoor ratios varied between 2 and 33) and to altered indoor particle size distributions. Cooking, including broiling/baking, toasting, and barbecuing contributed primarily to particulate matter with physical diameters between 0.02 and 0.5 mu m [PM(0.02-0.5)], with volume median diameters of between 0.13 and 0.25 mu m. Sources of particulate matter with aerodynamic diameters between 0.7 and 10 pm [PM(0.7-10)] included sauteing, cleaning (vacuuming, dusting, and sweeping), and movement of people, with volume median diameters of between 3 and 4.3 mu m Frying was associated with particles from both PM(0.02-0.5) and PM(0.7-10). Air exchange rates ranged between 0.12 and 24.3 exchanges/hr and had significant impact on indoor particle levels and size distributions. Low air exchange rates (< 1 exchange/hr) resulted in longer air residence times and more time for particle concentrations from indoor sources to increase. When air exchange rates were higher (> 1 exchange/hr), the impact of indoor sources was less pronounced, as indoor particle concentrations tracked outdoor levels more closely.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 43 条
  • [1] [Anonymous], AM REV RESP DIS
  • [2] BAHADORI T, 1998, THESIS HARVARD U
  • [3] BRUEL, 1990, INSTRUCTION MANUAL M
  • [4] Spatial variation in particulate concentrations within metropolitan Philadelphia
    Burton, RM
    Suh, HH
    Koutrakis, P
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (02) : 400 - 407
  • [5] CLAYTON CA, 1993, J EXPO ANAL ENV EPID, V3, P227
  • [6] AN ASSOCIATION BETWEEN AIR-POLLUTION AND MORTALITY IN 6 UNITED-STATES CITIES
    DOCKERY, DW
    POPE, CA
    XU, XP
    SPENGLER, JD
    WARE, JH
    FAY, ME
    FERRIS, BG
    SPEIZER, FE
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (24) : 1753 - 1759
  • [7] ACUTE RESPIRATORY EFFECTS OF PARTICULATE AIR-POLLUTION
    DOCKERY, DW
    POPE, CA
    [J]. ANNUAL REVIEW OF PUBLIC HEALTH, 1994, 15 : 107 - 132
  • [8] HEITBRINK WA, 1992, AM IND HYG ASSOC J, V53, P427, DOI 10.1202/0002-8894(1992)053<0427:AATEAC>2.0.CO
  • [9] 2
  • [10] COINCIDENCE IN TIME-OF-FLIGHT AEROSOL SPECTROMETERS - PHANTOM PARTICLE CREATION
    HEITBRINK, WA
    BARON, PA
    WILLEKE, K
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1991, 14 (01) : 112 - 126